DSC-RX100M3 (serv.man2) - Sony Digital Camera Service Manual (repair manual)

Model
DSC-RX100M3 (serv.man2)
Pages
31
Size
9.1 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / - LEVEL 2
File
dsc-rx100m3-sm2.pdf
Date

View Sony DSC-RX100M3 (serv.man2) Service Manual online

DSC-RX100M3_L2
Sony Corporation
SERVICE MANUAL
Revision History
SERVICE  NOTE (Check the following note before the service.)
LEVEL 
2
Published by Sony Techno Create Corporation
983479731.pdf
DIGITAL STILL CAMERA
The components identified by 
mark 
0 or dotted line with mark 
0 are critical for safety.
Replace only with part number 
specified.
Les composants identifiés par 
une marque 
0 sont critiques pour 
la sécurité.
Ne les remplacer que par une piè-
ce portant le numéro spécifié.
9-834-797-31
Ver.
Date
History
Contents
S.M. Rev.
issued
1.0
2014.05
Official Release
2014E08-1
  © 2014.05
– ENGLISH –
1-1.   PRECAUTION ON REPLACING THE SY-1036 BOARD
1-2.   NOTES ON REPLACING THE LENS
1-3.   NOTES ON REMOVING/INSTALLING THE IMAGER BOARD (CD-847 FLEXIBLE 
BOARD)
1-4.   NOTES FOR REPLACING THE EVF DISPLAY DEVICE (LCD902) OR THE SY-1036 
BOARD
1-5.  CHECKING THE Wi-Fi FUNCTION
1-6.   SELF-DIAGNOSIS FUNCTION
1-7.  PROCESS AFTER FIXING FLASH ERROR
1-8.   CLEANING OF THE EVF
1-9.   ORNAMENTAL RING (A) OR BARRIER BLOCK ASSY REPLACING METHOD 
1-10.  1 GROUP FRAME BLOCK ASSY REPLACING METHOD 
‒ JAPANESE ‒
1-1.   SY-1036基板交換時の注意
1-2.   レンズ交換時の注意
1-3.   イメージャ基板(CD-847フレキシブル基板)の取り外し/取り付け時の注意
1-4.   EVF表示素子(LCD902)またはSY-1036基板交換時の注意
1-5.   Wi-Fi機能の確認
1-6.   自己診断機能
1-7.   フラッシュエラー発生時の対処法
1-8.   EVFの清掃について
Ver. 1.0  2014.05
DSC-RX100M3
US Model
Canadian Model
AEP Model
UK Model
Russian Model
E Model
Hong Kong Model
Chinese Model
Korea Model
Japanese Model
Tourist Model
DSC-RX100M3_L2
– 2 –
SPECIFICATIONS
– ENGLISH –
– JAPANESE –
Camera 
[System] 
Image device: 13.2 mm × 8.8 mm
 
(1.0 type) Exmor R™ CMOS
 sensor
Total pixel number of camera:
 
Approx. 20.9 Megapixels
Effective pixel number of camera:
 
Approx. 20.1 Megapixels
Lens: ZEISS Vario-Sonnar T 2.9×
 zoom 
lens
 
f = 8.8 mm – 25.7 mm (24 mm –
 
70 mm (35 mm film equivalent))
 
F1.8 (W) – F2.8 (T)
 
While shooting movies (16:9):
 
25.5 mm – 74 mm
*1
 
While shooting movies (4:3):
 
31 mm – 90 mm
*1
 
*1
 When [
 SteadyShot] is set to [Standard]
SteadyShot: Optical
File format:
 
Still images: JPEG (DCF, Exif,
 
MPF Baseline) compliant, RAW
 
(Sony ARW 2.3 Format), DPOF
 compatible
 
Movies (XAVC S format):
 
MPEG-4 AVC/H.264 XAVC S
 
ver.1.0 format compliant
 Video: 
MPEG-4 
AVC/H.264
 
Audio: Linear PCM 2ch (48 kHz
 16 
bit)
 
Movies (AVCHD format):
 
AVCHD format Ver. 2.0
 compatible
 Video: 
MPEG-4 
AVC/H.264
 
Audio: Dolby Digital 2ch,
 
equipped with Dolby Digital Stereo
 Creator
•  Manufactured under license from 
Dolby Laboratories.
 
Movies (MP4 format):
 Video: 
MPEG-4 
AVC/H.264
 
Audio: MPEG-4 AAC-LC 2ch
Recording media: Memory Stick PRO
 
Duo media, Memory Stick Micro
 
media, SD cards, microSD memory
 cards
Flash: Flash range (ISO sensitivity
 
(Recommended Exposure Index)
 set 
to 
Auto):
 
Approx. 0.4 m to 10.2 m
 
(1.31 ft. to 33.46 ft.) (W)/
 
Approx. 0.4 m to 6.5 m
 
(1.31 ft. to 21.33 ft.) (T)
[Input and Output connectors]
HDMI connector: HDMI micro jack
Multi/Micro USB Terminal*:
 USB 
communication
USB communication: Hi-Speed USB
 (USB 
2.0)
* Supports Micro USB compatible device.
[Viewfinder]
Type: Electronic viewfinder (Organic
 Electro-Luminescence)
Total number of dots:
 
1 440 000 dots
Frame coverage: 100%
Magnification: Approx. 0.59 ×
 
(35 mm-format equivalent) with 
50 mm lens at infinity, –1 m
–1
Eye point: Approx. 20 mm from the
 
eyepiece, 19.2 mm from the
 
eyepiece frame at –1 m
–1
* Diopter adjustment:
 –4.0 
m
–1
 to +3.0 m
–1
[Monitor]
LCD monitor:
 
7.5 cm (3.0 type) TFT drive
Total number of dots:
 
1 228 800 dots
[Power, general]
Power: Rechargeable battery pack
 NP-BX1, 
3.6 
V
 
AC Adaptor AC-UB10C/UB10D,
 5 
V
Power consumption:
 
Approx. 1.7 W (during shooting
 
with the monitor)
 
Approx. 2.3 W (during shooting
 
with the viewfinder)
Operating temperature: 0 °C to 40 °C
 
(32 °F to 104 °F)
Storage temperature: –20 °C to +60 °C
 
(–4 °F to +140 °F)
Dimensions (CIPA compliant):
 
101.6 mm × 58.1 mm × 41.0 mm
 
(4 inches × 2 3/8 inches ×
 
1 5/8 inches) (W/H/D)
Mass (CIPA compliant) (Approx.):
 
290 g (10.2 oz) (including NP-BX1
 
battery pack, Memory Stick PRO
 Duo 
media)
Microphone: Stereo
Speaker: Monaural
Exif Print: Compatible
PRINT Image Matching III:
 Compatible
[Wireless LAN]
Supported standard: IEEE 802.11 b/g/n
Frequency: 2.4GHz
Supported security protocols: WEP/
 WPA-PSK/WPA2-PSK
Configuration method: WPS (Wi-Fi
 
Protected Setup) / manual
Access method: Infrastructure Mode
NFC: NFC Forum Type 3 Tag
 compliant
Model No. WW808161
AC Adaptor AC-UB10C/UB10D
Power requirements: AC 100 V to
 
240 V, 50 Hz/60 Hz, 70 mA
Output voltage: DC 5 V, 0.5 A
Rechargeable Battery Pack
NP-BX1
Battery type: Lithium-ion battery
Maximum voltage: DC 4.2 V
Nominal voltage: DC 3.6 V
Maximum charge voltage: DC 4.2 V
Maximum charge current: 1.89 A
Capacity: Typical 4.5 Wh (1 240 mAh)
Design and specifications are subject to
change without notice.
Model information table
Model
DSC-RX100M3
Destination
US, CND, E, KR, J
AEP, UK, RU, E, HK, CH, JE
Color system
NTSC
PAL
GPS
Wi-Fi
NFC
• Abbreviation
  CH :  Chinese model
  CND :  Canadian model
  HK :  Hong Kong model
  J : 
Japanese model
  JE : 
Tourist model
  KR :  Korea model
 RU  : 
Russian 
model
概略仕様
本体
[システム]
撮像素子:
13.2 mm
×
8.8 mm
1.0
型)
 Exmor 
R
TM
 CMOS
センサー
総画素数:約
2090
万画素
カメラ有効画素数:約
2010
万画素
レンズ:
 ZEISS 
バリオ・ゾナー
T*
 2.9
倍ズームレンズ
 f=8.8 
mm
 
25.7 mm
 
24 
mm
 
 70 mm
35 mm
フィルム
 
換算値))、
F1.8 (W) 
 F2.8 (T)
 
動画撮影時(
16
9
):
 25.5 
mm
 
 74 mm
*1
 
動画撮影時(
4
3
):
 31 
mm
 
 90 mm
*1
*1
 
 
手ブレ補正]が[スタンダード]のとき
手ブレ補正:光学式
記録方式:
 
静止画記録方式:
 JPEG
DCF
Exif
MPF Baseline
)準拠、
 RAW
(ソニー
ARW 2.3
フォーマット)、
 DPOF
対応
 
動画記録方式(
XAVC S
方式):
 
MPEG-4 AVC/H.264 XAVC S ver.1.0
 
規格準拠
 
映像:
MPEG-4 AVC/H.264
 
音声:リニア
PCM 2ch
48kHz 16bit
 
動画記録方式(
AVCHD
方式):
 AVCHD
規格
 Ver.2.0
準拠
 
映像:
MPEG-4 AVC/H.264
 
音声:
Dolby Digital 2ch
 
ドルビーデジタルステレオクリエーター搭載
 
ドルビーラボラトリーズからの実施権に基づ
き製造されています。
 
動画記録方式(
MP4
方式):
 
映像:
MPEG-4 AVC/H.264
 
音声:
MPEG-4 AAC-LC 2ch
記録メディア:
 
メモリースティック
 PRO 
デュオ、
メモリースティック
 
マイクロ、
SD
カード、
microSD 
メモリーカード
フラッシュ:撮影範囲(
ISO
感度(推奨露光
 
指数)がオートのとき)
 
0.4 
m∼約
10.2 m (W)/
 
0.4 
m∼約
6.5 m (T)
[入出力端子]
HDMI
端子:
HDMI
マイクロ端子
マルチ
/
マイクロ
USB
端子
*
USB
通信
USB
通信:
Hi-Speed USB
USB 2.0
この端子にはマイクロ
USB
規格に対応した機器をつ
なぐことができます。
[ファインダー]
形式:電子式ビューファインダー(有機
EL
総ドット数:
1 440 000
ドット
視野率:
100
倍率:約
0.59
倍(
35mm
判換算、
50 mm
レンズ、
 
無限遠、視度−
1 m
−1
時)
アイポイント:最終光学面から約
20 mm
 
接眼枠から約
19.2 
mm(視度−
1 m
−1
時)
視度調整:−
4.0 m
−1
∼+
3.0 m
−1
[モニター]
液晶モニター:
 7.5 
cm
3.0
型)、
TFT
駆動
総ドット数:
1 228 800
ドット
[電源・その他]
電源:リチャージャブルバッテリーパック
 NP-BX1
3.6 V
 AC
アダプター
 AC-UB10C/UB10D
 5 
V
消費電力:
 
1.7 W
(モニターで撮影時)
 
2.3 W
(ファインダーで撮影時)
動作温度:
℃∼
40 
保存温度:−
20 
℃∼
+60 
外形寸法(
CIPA
準拠)
(約):
 101.6 
mm
×
58.1 mm
×
41.0 mm
 
(幅×高さ×奥行き)
本体質量(
CIPA
準拠)
(約):
 290 
g
(バッテリー
NP-BX1
 
メモリースティック
 PRO 
デュオを含む)
マイクロホン:ステレオ
スピーカー:モノラル
Exif Print
:対応
PRINT Image Matching III
:対応
[ワイヤレスLAN]
対応規格:
IEEE 802.11b/g/n
使用周波数帯:
2.4GHz
セキュリティー:
WEP/WPA-PSK/
 WPA2-PSK
接続方式:
WPS
Wi-Fi Protected Setup
 
/
マニュアル
アクセス方式:インフラストラクチャーモード
NFC
NFC
フォーラム
 Type 3 Tag
準拠
Model No. WW808161
ACアダプター
AC-UB10C/UB10D
定格入力:
AC 100 V
240 V
 
50 Hz/60 Hz
70 mA
定格出力:
DC 5 V
0.5 A
リチャージャブルバッテリー
パックNP-BX1
使用電池:リチウムイオン電池
最大電圧:
DC 4.2 V
公称電圧:
DC 3.6 V
容量:
4.5 Wh
1 240 mAh
本機や付属品の仕様および外観は、改良のため予告
なく変更することがありますが、ご了承ください。
DSC-RX100M3_L2
– 3 –
SAFETY-RELATED  COMPONENT  WARNING!!
COMPONENTS IDENTIFIED BY MARK 0 OR DOTTED LINE WITH 
MARK 
0 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS LIST 
ARE CRITICAL TO SAFE OPERATION. REPLACE THESE COMPO-
NENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS 
SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUBLISHED BY 
SONY. 
ATTENTION AU  COMPOSANT  AYANT  RAPPORT 
À  LA  SÉCURITÉ!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 0 SUR LES 
DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT 
CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE REM-
PLACER CES COMPOSANTS QUE PAR DES PIÈCES SONY DONT 
LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU DANS LES 
SUPPLÉMENTS PUBLIÉS PAR SONY.
Caution
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type.
Dispose of used batteries according to the instructions.
注意
電池の交換は,正しく行わないと破裂する恐れがあります。
電池を交換する場合には必ず同じ型名の電池又は同等品と
交換してください。
使用済み電池は,取扱指示に従って処分してください。
UNLEADED SOLDER
This unit uses unleaded solder.
Boards requiring use of unleaded solder are printed with the lead free 
mark (LF) indicating the solder contains no lead.
(Caution:  Some printed circuit boards may not come printed with the 
lead free mark due to their particular size.)
: LEAD FREE MARK
Be careful to the following points to solder or unsolder.
•   Set the soldering iron tip temperature to 350 °C approximately. 
If cannot control temperature, solder/unsolder at high temperature 
for a short time.
Caution:  The printed pattern (copper foil) may peel away if the 
heated tip is applied for too long, so be careful!  
Unleaded solder is more viscous (sticky, less prone to 
flow) than ordinary solder so use caution not to let solder 
bridges occur such as on IC pins, etc.
•   Be sure to control soldering iron tips used for unleaded solder and 
those for leaded solder so they are managed separately. Mixing un-
leaded solder and leaded solder will cause detachment phenomenon.
SAFETY  CHECK-OUT
After correcting the original service problem, perform the following 
safety checks before releasing the set to the customer.
1.  Check the area of your repair for unsoldered or poorly-soldered 
connections. Check the entire board surface for solder splashes and 
bridges.
2.  Check the interboard wiring to ensure that no wires are “pinched” 
or contact high-wattage resistors.
3.  Look for unauthorized replacement parts, particularly transistors, 
that were installed during a previous repair. Point them out to the 
customer and recommend their replacement.
4.  Look for parts which, through functioning, show obvious signs of 
deterioration. Point them out to the customer and recommend their 
replacement.
5.  Check the B+ voltage to see it is at the values specified.
6.  Flexible Circuit Board Repairing
 
•   Set the soldering iron tip temperature to 350 °C approximately.
 
•   Do not touch the soldering iron on the same conductor of the circuit 
board (within 3 times).
 
•   Be careful not to apply force on the conductor when soldering or 
unsoldering.
1.  注意事項をお守りください。
 
サービスのとき特に注意を要する個所については,キャビ
ネット,シャーシ,部品などにラベルや捺印で注意事項を
表示しています。これらの注意書き及び取扱説明書等の注
意事項を必ずお守り下さい。
2.  指定部品のご使用を
 
セットの部品は難燃性や耐電圧など安全上の特性を持った
ものとなっています。従って交換部品は,使用されていた
ものと同じ特性の部品を使用して下さい。特に回路図,部
品表に0印で指定されている安全上重要な部品は必ず指定
のものをご使用下さい。
3.  部品の取付けや配線の引きまわしはもとどおりに
 
安全上,チューブやテープなどの絶縁材料を使用したり,
プリント基板から浮かして取付けた部品があります。また
内部配線は引きまわしやクランパによって発熱部品や高圧
部品に接近しないよう配慮されていますので,これらは必
ずもとどおりにして下さい。
4.  サービス後は安全点検を
 
サービスのために取外したネジ,部品,配線がもとどおり
になっているか,またサービスした個所の周辺を劣化させ
てしまったところがないかなどを点検し,安全性が確保さ
れていることを確認して下さい。
5.  チップ部品交換時の注意
 
・  取外した部品は再使用しないで下さい。
 
・  タンタルコンデンサのマイナス側は熱に弱いため交換時
は注意して下さい。
6.  フレキシブルプリント基板の取扱いについて
 
・  半田こてのこて先温度は約350℃に設定してください。
 
・  同一パターンに何度もコテ先を当てないで下さい。(3回
以内)
 
・  パターンに力が加わらないよう注意して下さい。
サービス,点検時には次のことにご注意ください。
無鉛半田について
本機には無鉛半田が使用されています。
無鉛半田を使用している基板には,無鉛(Lead Free)を意味する
レッドフリーマークがプリントされています。
(注意: 基板サイズによっては,無鉛半田を使用していてもレッ
ドフリーマークがプリントされていないものがありま
す)
:レッドフリーマーク
無鉛半田は,下記の点に注意して使用してください。
・  半田こてのこて先温度は約350℃に設定してください。
温度調節が無理な場合は,高温短時間で作業を行ってくだ
さい。
注意:  半田こてを長く当てすぎると,基板のパターン(銅
箔)がはがれてしまうことがありますので,注意して
ください。また,従来の半田よりも粘性が強いため,
IC端子などが半田ブリッジしないように注意してく
ださい。
・  半田こてのこて先は,必ず無鉛半田用と有鉛半田用に分け
て管理してください。
無鉛半田と有鉛半田が混在すると剥離現象が発生してしま
います。
– ENGLISH –
– JAPANESE –
注意
如果电池更换不当会有爆炸危险。
只能用同样类型或等效类型的电池来更换。
务必按照说明处置用完的电池。
DSC-RX100M3_L2
1-1
1. SERVICE  NOTE
1-1.  PRECAUTION ON REPLACING THE SY-1036 BOARD
DESTINATION DATA
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATION DATA WRITE”.
RESTORE DATA
When you replace to the repairing board, get the data from the former one.
Start the Adjust Manual in the Adjust Station and perform “RESTORE DATA” to get the data. 
The data getting for this model is as follows.
• PRODUCT ID & USB SERIAL No. INPUT
• Lens data carry
• AWB adj
• Light sensor adj
• Eye sensor adj
• EVF Data Input
USB Serial No. and Product ID
The unit is shipped after an ID (USB Serial No.) unique to each unit and an ID (Product ID) unique to each model have been written.
These IDs have not been written in a new board for service, and therefore they must be entered after the board replacement.
After the board has been replaced with a board for service, start the Adjust Manual in the Adjust Station and execute the “PRODUCT ID & USB 
SERIAL No. INPUT” and enter these IDs.
Note: A newly entered Product ID is not always equal to the ID before board replacement. If the new ID differs from the previous ID, it may cause a difference from 
the ID registered by the customer.
Update of MAC Address
When a board that contains Wi-Fi has been replaced or when replacing a board that contains the main IC (CPU), the IC’s unique number (MAC ad-
dress) must be reloaded.
Perform the following procedure to reload the IC’s unique number (MAC address).
1.  Download the latest-version Adjust Manual.
2.  Install the downloaded Adjust Manual.
3.  Start the Adjust Manual, and execute “Wireless LAN check” on the ADJUST tab.
4.  Perform the following operations for the unit to initialize.
 MENU 
→   → [Reset Network Set.] → [OK] → ●
5.  Perform the following operations for the unit to display MAC address.
 MENU 
→   → [Disp MAC Address] → ●
6.  Confirm that the displayed MAC address has been updated.
Applicable parts
•  SY-1036 BOARD, COMPLETE (SERVICE)
 
Note: The LOAD AND WRITE function in ADJUSTMENT DATA BACKUP on the DATA tab in the Adjust manual overwrites all data of the unit.
 
Therefore, the MAC address updated during the above procedure is also overwritten.
Perform the above operations after all work has been done.
After the replacement and repair, the MAC address is changed, and thus the re-setting for connection devices is required. Accordingly, download the 
Flyer of WLAN Reset (Flyer of WLAN Reset_9834752[][].pdf) and print out it, and attach it to the set when returning the set to customer.
– ENGLISH –
Angular Velocity Sensor
When you replace to the repairing board, write down the sensitivity displayed on the angular velocity sensor (SE7701).
Start the Adjust Manual in the Adjust Station and execute the “Angular velocity sensor sensitivity ADJ”.
Type A:
Type B:
P Y
P Y
P: PITCH sensor sensitivity
Y: YAW sensor sensitivity
SY-1036 BOARD (SIDE A)
SE7701
Note: The sensor sensitivity of SE7701 of SY-1036 board is written only repair parts.
1-2.  NOTES ON REPLACING THE LENS
When replacing the lens, read the QR code of the repair lens.
To read the QR code, start the Adjust manual and press the QR code reader button.
The read data is used in the following processes.
•  Selection of Spacer Plate when mounting the imager board
•  Adjustment after replacing the lens
1-2-1.
 
Selection of Spacer Plate when Mounting the Imager Board
1.  Load the Spacer Plate on the QR code reader screen.
2.  The thickness of the Spacer Plate to be loaded is displayed.
 
3.  Select the Spacer Plate according to the instructions on the screen and mount the imager board.
1-2-2.
 
Adjustment after Replacing the Lens
Perform LOAD from “Lens data carry” on the ADJUST tab in the Adjust manual.
QR code
DSC-RX100M3_L2
1-2
– ENGLISH –
1-3.  NOTES ON REMOVING/INSTALLING THE IMAGER BOARD (CD-847 FLEXIBLE BOARD)
When the CD-847 Flexible Board (Imager) is mounted to the lens, shift and tilt adjustment is made with Spacer Plates.
When removing the CD-847 Flexible Board, pay attention to the following.
(1)  When the lens is not replaced
 
Example: In the case of disassembly, cleaning, or replacement of the CD-847 Flexible Board (Imager)
•  Check and record the size of the built-in three Spacer Plates and store them so as not to lose them.
•  When assembling the CD-847 Flexible Board, be sure to install the Spacer Plates to their original locations.
Size
0.xx
Note
Be careful not to lose the Spacer Plates.
If any Spacer Plate is lost or their previous positions are not sure, repeatedly take a photo and check that there is no local defocus. 
Selecting appropriate Spacer 
Plates
 is needed.
(2)  When the lens is replaced
 
Refer to “1-2. NOTES ON REPLACING THE LENS” for select Spacer Plates and install them to the new lens.
1-4.  NOTES FOR REPLACING THE EVF DISPLAY DEVICE (LCD902) OR THE SY-1036 BOARD
Adjustment values of each EVF display device (LCD902) are stored on the SY board.
Therefore, when the LCD902 or the SY board has been replaced, write adjustment values.
White balance value
Brightness value
2565687041A
Example of the label which is put on repairing EVF display device (LCD902)
Note:  When a label is mention such as the illustration, please read it follows.
 
Brightness value: 256
 
White balance value: 874
When LCD902 is replaced:
1.  Check and write down the adjustment values printed on the repairing EVF display device (LCD902) label.
2.  After the LCD902 has been replaced, execute “EVF Data Input” on the ADJUST tab by using the Adjust manual to write the adjustment values.
When replacing SY board (in case adjustment values can be read):
1.  In case the unrepaired unit starts and adjustment values can be read by using the Adjust manual, execute “ADJUSTMENT DATA BACKUP” on 
the DATA tab.
2.   After the SY board has been replaced with a SY board for repair, execute “ADJUSTMENT DATA BACKUP” on the DATA tab of the Adjust 
manual to write the extracted data to the unit.
When replacing SY board (in case adjustment values cannot be read):
Consult with each Head Quarters.
DSC-RX100M3_L2
1-3
– ENGLISH –
1-5.  CHECKING THE Wi-Fi FUNCTION
Perform the following procedure to check the Wi-Fi function.
Required equipment: Windows personal computer with Wi-Fi interface
1.  Turn on the power of the unit.
2.  Perform the following operations.
 MENU 
→   → [Application List] → [Smart Remote Embedded] → ●
3.  When preparation for Wi-Fi has been completed, the following screen opens and a password for Wi-Fi connection is displayed.
Smart Remote Embedded
Operate smartphone to connect to
this device via Wi-Fi.
SSID DIRECT-XXXX:DSC-XXXX
Password XXXXXXXX
Device Name DSC-XXXX
Wi-Fi
Exit App.
4.  Confirm on the personal computer that the unit is detected as a connectable wireless network.
5.  To further confirm that the unit is connectable, connect the unit to the personal computer and double-click the “current connection” from the icon 
displayed on the notice field, make sure that the unit is displayed in the Wireless internet access column.
1-6. SELF-DIAGNOSIS FUNCTION
1-6-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis 
function starts working, and displays on the LCD screen what to do.
Details of the self-diagnosis functions are provided in the Instruction 
manual.
1-6-2. Self-diagnosis Display
When problems occur while the unit is operating, the LCD screen shows 
a 4-digit display consisting of an alphabet and numbers, which blinks 
at 3.2 Hz. This 5-character display indicates the “repaired by:”, “block” 
in which the problem occurred, and “detailed code” of the problem.
0 0
3 2
C
Repaired by:
Refer to “1-6-3. Self-diagnosis Code Table”.
Indicates the appropriate
step to be taken.
E.g.
13 ....Format the “memory card”.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2 Hz
C : Corrected by customer
E : Corrected by service
engineer
LCD screen
1-6-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
1
3
0
1
Memory card is unformatted.
Format the memory card.
Memory card is broken.
Insert a new memory card.
Memory card type error
Insert a supported memory card.
The camera cannot read or write data on the 
memory card.
Turn the power off and on again, or taking out and inserting the 
memory card several times.
C
3
2
0
1
Trouble with hardware
Turn the power off and on again.
E
4
1
0
0
Abnormality of wireless LAN module or 
host  CPU.
Replace the SY-1036 board.
E
4
1
0
1
Abnormality of network control device.
Turn the power off and on again.
E
6
1
0
0
Difficult to adjust focus
(Cannot initialize focus)
Retry turn the power on by the power switch. If it does not recover, 
check the focus MR sensor signal of lens block (pin 4, 5 of CN6800 
on the SY-1036 board). If it is OK, check the focus motor drive IC 
(IC6802 on the SY-1036 board).
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Retry turn the power on by the power switch. Check the zoom reset 
sensor signal of lens block (pin 1 of CN6800 on the SY-1036 board) 
when zooming is performed when the zoom button is operated. If it is 
OK, check the zoom motor drive IC (IC6802 on the SY-1036 board).
E
6
1
3
0
Reset position detection error on the stepper
iris initializing
Turn power off and turn power on again.
E
6
2
0
2
Abnormality of IC for steadyshot.
Check or replacement of the IC for steadyshot (IC6802 on the SY-
1036 board).
DSC-RX100M3_L2
1-4
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
6
2
1
0
Lens initializing failure.
Check or replacement of the IC for steadyshot (IC6802 on the SY-
1036 board).
E
6
2
1
1
Lens overheating (PITCH).
Check the HALL element (PITCH) of optical image stabilizer (pin 
wh
, wk of CN6800 on the SY-1036 board). If it is OK, check PITCH 
angular velocity sensor (SE7701 on the SY-1036 board) peripheral 
circuits.
E
6
2
1
2
Lens overheating (YAW).
Check the HALL element (YAW) of optical image stabilizer (pin wd, 
wg
 of CN6800 on the SY-1036 board). If it is OK, check YAW angular 
velocity sensor (SE7701 on the SY-1036 board) peripheral circuits.
E
6
2
2
0
Abnormality of thermistor.
Check the temp sensor of optical image stabilizer (pin 9 of CN6800 
on the SY-1036 board).
E
9
1
0
1
Abnormality when flash is being charged.
Checking of flash unit or replacement of flash unit. (Note 1)
E
9
2
0
0
Battery / Dry cell distinction defect
Turn power off and turn power on again.
E
9
4
0
0
Internal memory fault
Inspect the internal memory (IC6000 on the SY-1036 board).
E
9
5
0
0
GPS hardware error
Turn power off and turn power on again.
E
9
5
0
1
Acceleration sensor hardware error 
Turn power off and turn power on again.
E
9
5
0
2
Electronic compass hardware error 
(GPS hardware error)
Turn power off and turn power on again.
Note 1:  After repair, be sure to perform “1-7. PROCESS AFTER FIXING FLASH ERROR”.
Note 2:  Functions of codes with * mark are not provided in this unit.
1-7.  PROCESS AFTER FIXING FLASH ERROR
When “FLASH error” (Self-diagnosis Code E : 91 : 01) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash is changed 
automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated.
Method for Initializing the Flash Error Code
Reset Flash Error using the Flash Error Repair Tool Ver_[].[].exe.
*
*
1-8.  CLEANING OF THE EVF
This unit makes it possible to disassemble the EVF from the finished state to clean it.
When a problem related to dust is indicated from a customer, remove the VF Unit Assy in the following procedure and clean it.
When cleaning the VF Unit Assy, use birdlime or the like to remove dust. (Recommended jig: J-6082-726-A CLEANING STICK II)
Note 1:  Carry out the cleaning work in a clean environment to avoid dust or foreign matter during disassembling.
 
Use a clean booth if possible.
Note 2:  Do not use an air blower because it raises surrounding dust.
Note 3:  Do not use cleaning cloth that causes wiping unevenness.
1-8-1. Removing the VF Unit Assy
Preparation:
Create a jig as shown below by bending fine wire.
Approx. 30 mm
Approx. 5 mm
Approx.     0.7 mm
Approx. 30 mm
Procedure
:
1.  Depress the viewfinder pop-up switch to pop up the EVF.
2.  Draw the VF Unit Assy.
1
2
Viewfinder 
pop-up switch
Holes
3.  Insert both ends of the jig into the holes of the VF Unit Assy, gently hold the jig, and then pull out the VF Unit Assy while pushing the internal 
bosses.
Note 1: Do not scratch the main body with the jig.
VF Unit Assy
– ENGLISH –
Be careful not to touch the 
grease applied to below 
part.
Note 2:
Grease
DSC-RX100M3_L2
1-5
1-1.  SY-1036基板交換時の注意
仕向けデータ
補修用基板と交換する時,補修用基板に書かれている仕向けデータは元の設定と違っている場合があります。
Adjust StationからAdjust Manualを起動させて「DESTINATION DATA WRITE」を実行させてください。
リストアデータ
補修用基板と交換する時,交換前の基板よりデータを取得してください。
データの取得はAdjust StationからAdjust Manualを起動させて「RESTORE DATA」を実行させてください。
本機で取得されるデータは下記になります。
・ PRODUCT ID & USB SERIAL No. INPUT
・ Lens data carry
・ AWB adj
・ Light sensor adj
・ Eye sensor adj
・ EVF Data Input
USBシリアルNo.およびプロダクトIDについて
本機はセット固有のID(USBシリアルNo.)と機種固有のID(プロダクトID)を書き込んだ後に出荷されています。
新品の補修用基板にはこれらのIDが書き込まれていないため,基板交換後にIDを入力する必要があります。
補修用基板に交換した後はAdjust StationからAdjust Manualを起動し,「PRODUCT ID & USB SERIAL No. INPUT」を実行させてIDを入
力してください。
Note:  新しくプロダクトIDを入力すると,必ずしも基板交換前のIDと同じIDになるとは限りません。新しいIDと元のIDが違う場合にはお客様がユーザー登録さ
れているIDと相違が出てしまう可能性があります。
MAC アドレスの更新
Wi-Fi 搭載基板を交換した時,またはメイン IC (CPU) が搭載されている基板を交換した場合,IC の固有番号 (MAC アドレス) を取り
込み直す必要があります。
下記の作業を実施して,IC の固有番号 (MAC アドレス) を取り込み直してください。
1.  最新版のAdjust Manualをダウンロードする。
2.  ダウンロードしたAdjust Manualをインストールする。
3.  Adjust Manualを起動し,ADJUSTタブにある「Wireless LAN check」を実施する。
4.  セット本体を下記のように操作し,設定リセットを行う。
 
MENU →   → [ネットワーク設定リセット] →[確認] → 中央の●で決定
5.  セット本体を下記のように操作し,MACアドレスを表示する。
 
MENU →   → [MACアドレス表示] → 中央の●で決定
6.  MACアドレスの表示が更新されていることを確認する。
対象となる部品
・  SY-1036 BOARD, COMPLETE (SERVICE)
Note:  Adjust manual 内の DATA タブにある,ADJUSTMENT DATA BACKUP にある機能,LOAD AND WRITE は,セットの全てのデータを上書きします。
 
そのため,上記の操作で更新した MAC アドレス も上書きされてしまいます。
上記の操作は全ての作業を実施した後に行ってください。
交換修理後はMACアドレスが変更されていますので,お客様に接続機器の再設定をしていただく必要があります。
そのためFlyer of WLAN Reset(Flyer of WLAN Reset_9834752[][].pdf)をダウンロードしてプリント出力し,セットに添付して返却し
てください。
– JAPANESE –
角速度センサ
補修用基板と交換する時,角速度センサ(SE7701)の感度表示を書き留めてください。
Adjust StationからAdjust Manualを起動させて「Angular velocity sensor sensitivity ADJ」を実行させてください。
Type A:
Type B:
P Y
P Y
ᵮᵘᴾᵮᵧᵲᵡᵦᴾज़ࡇᘙᅆ
ᵷᵘᴾᵷᵟᵵᴾज़ࡇᘙᅆ
SY-1036 BOARD (SIDE A)
SE7701
Note:SY-1036基板のSE7701感度表示は補修用基板にしか記載されておりません。
1-2.  レンズ交換時の注意
レンズを交換する際は補修用レンズのQRコードを読み取ってください。
QRコードの読み取りは,Adjust  manualを起動してQRコードリーダーボタンより実行
してください。
読み取ったデータは以下の工程において使用します。
・イメージャ基板取り付け時のあおり板の選択
・交換終了後の調整時
1-2-1. イメージャ基板取り付け時のあおり板の選択
1.  QRコードリーダー画面にて読み込みを実行する。
2.  組み込むあおり板の厚みが表示される。
 
3.  画面の指示に合わせてあおり板を選択し,イメージャ基板を取り付ける。
1-2-2. 交換終了後の調整時
Adjust manualのADJUSTタブにある,
「Lens data carry」よりLOADを実施してください。
QR
コード
DSC-RX100M3_L2
1-6
– JAPANESE –
1-3.  イメージャ基板 (CD-847フレキシブル基板) の取り外し/取り付け時の注意
CD-847フレキシブル基板(イメージャ)は,レンズに取り付ける際,あおり板によりあおり調整されています。
CD-847フレキシブル基板を取り外すときは,下記の事に注意して作業してください。
(1)  レンズを交換しない作業の場合
例: 分解清掃する場合,CD-847フレキシブル基板(イメージャ)を交換する場合など。
・  組み込まれているあおり板(3箇所)のサイズを確認/記録し,失くさないように保管する。
・  組立時には,あおり板を必ず元通りの位置に取り付ける。
サイズ
0.xx
注意
あおり板を紛失しないように注意してください。
あおり板を紛失してしまったり,あおり板の元の位置がわからなくなってしまったときには実写して片ボケがないことの確認を繰り返し,
適切な
あおり板を選択
する必要があります。
(2)  レンズを交換する作業の場合
 
1-2. レンズ交換時の注意 を参照し,あおり板を選択してから新しいレンズに取り付ける。
1-4.   EVF表示素子(LCD902)またはSY-1036基板交換時の注意
本機ではEVF表示素子(LCD902)ごとの調整値がSY基板に書き込まれています。
このためLCD902またはSY基板を交換した場合には調整値の書き込みを行ってください。
ホワイトバランスの値
輝度の値
2565687041A
補修用EVF表示素子(LCD902)に貼られているラベルの例
Note:  ラベルがイラストのような記載であった場合, 下記のように読み取ってください。
 
輝度の値: 256
 
ホワイトバランスの値: 874
LCD902交換時
1.  補修用EVF素子(LCD902)のラベルに印字されている調整値を確認し,控えておく。
2.  交換作業が完了したらAdjust manualを使用し,ADJUSTタブにある「EVF Data Input」を実行する。
SY基板交換時 (調整値を読み取り可能な場合)
1.  修理前のセットが起動し,Adjust  manualを使用し調整値を読み取ることが可能な場合は,DATAタブにある「ADJUSTMENT 
DATA BACKUP」を実行する。
2.  補修用SY基板に交換した後,抽出したデータをAdjust manualのDATAタブにある「ADJUSTMENT DATA BACKUP」を実行してセッ
トに書き込む。
SY基板交換時 (調整値を読み取り不可能な場合)
サービスHQへお問い合わせください。
DSC-RX100M3_L2
1-7
1-5.  Wi-Fi機能の確認
Wi-Fi 機能を確認するときは以下の手順で行ってください。
用意する機器: Wi-Fi接続の可能なWindowsパソコン
1.  本機の電源を入れる。
2.  セット本体を下記のように操作する。
 
MENU →   →[アプリ一覧]→[スマートリモコン内蔵版]→ 中央の●で決定
3.  Wi-Fi準備が完了すると以下の画面に切り替わり,Wi-Fi接続のためのパスワードが表示される。
スマートリモコン内蔵版
スマートフォンを操作して
本機にWi-Fi接続してください
アプリ終了
Wi-Fi
SSID DIRECT-XXXX:DSC-XXXX
パスワード XXXXXXXX
機器名称 DSC-XXXX
4.  パソコン側で接続可能なワイヤレスネットワークとして,本機が検出されることを確認する。
5.  さらに接続可能なことを確認したい場合には本機とパソコンを接続後,通知領域に表示されているアイコンから「現在の接続先」   
をダブルクリックし,ワイヤレスインターネットアクセスの欄に本機が表示される事を確認する。
– JAPANESE –
1-6.  自己診断機能
1-6-1. 自己診断機能について
本機の動作に不具合が生じたとき,自己診断機能が働き,LCD
画面に,どう処置したらよいか判断できる表示を行います。自
己診断機能については取扱説明書にも掲載されて
います。
1-6-2. 自己診断表示
本機の動作に不具合が生じたとき,LCD画面にアルファベッ
トと4桁の数字が表示され,3.2Hzで点滅します。この5文字の
表示によって対応者分類および不具合の生じたブロックの分
類,不具合の詳細コードを示します。
0 0
C
2
3
対応者分類 
「1-6-3. 自己診断コード表」を参照
対応方法の違いにより分類
・メモリーカードをフォーマットする
3
1
32 ・・・電源を入れ直す
ブロック分類 
詳細コード 
3.2 Hz点滅
C :お客さま自身で対応
E :サービスエンジニア
で対応
LCD画面
1-6-3. 自己診断コード表
自己診断コード
症状/状態
対応/方法
ブロック
機能
詳細
コード
C
1
3
0
1
フォーマットしていないメモリーカー
ドを入れた。
メモリーカードをフォーマットする。
メモリーカードが壊れている。
新しいメモリーカードに交換する。
メモリーカードのタイプエラーを検出
した。
規格内のメモリーカードを挿入する。
メモリーカードが読み/書きできない。
電源の入れ直し,またはメモリーカードの挿し/外しを数回
試す。
C
3
2
0
1
ハードウェアトラブルを検出した。
電源を入れ直す。
E
4
1
0
0
ワイヤレスLANモジュール,またはホ
ストCPUの異常。
SY-1036基板を交換する。
E
4
1
0
1
ネットワーク制御デバイスの異常。
電源を入れ直す。
E
6
1
0
0
フォーカスが合いにくい。
(フォーカスの初期化ができない)
操作スイッチの電源を入れ直す。
復帰しない場合はレンズブロックのフォーカスMRセンサー
信号(SY-1036基板CN6800 4,5ピン)を点検する。
異 常 な け れ ば フ ォ ー カ ス モ ー タ 駆 動IC(SY-1036基 板
IC6802)を点検する。
E
6
1
1
0
ズーム動作の異常。
(ズームレンズの初期化ができない)
操作スイッチの電源を入れ直す。
ズームボタンを操作したときにズーム動作をすればレン
ズブロックのズームリセットセンサー信号(SY-1036基板
CN6800 1ピン)を点検する。
異常なければズームモータ駆動IC(SY-1036基板IC6802)を
点検する。
E
6
1
3
0
ステッパIRISイニシャル時リセット位
置検出異常
電源を入れ直す。

Download Sony DSC-RX100M3 (serv.man2) Service Manual (Repair Manual)

Here you can view online and download Sony DSC-RX100M3 (serv.man2) Service Manual in PDF. DSC-RX100M3 (serv.man2) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sony DSC-RX100M3 (serv.man2) Digital Camera. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.