DSC-RX1 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 4

Read Sony DSC-RX1 (serv.man2) Service Manual online

DSC-RX1_L2
1-1
1. SERVICE  NOTE
1-1.  NOTES ON REPLACING THE SY-1001 BOARD
DESTINATION DATA
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATION DATA WRITE”.
RESTORE DATA
When you replace to the repairing board, get the data from the former one.
Start the Adjust Manual in the Adjust Station and perform “RESTORE DATA” to get the data. 
The data getting for this model is as follows.
• PRODUCT ID & USB SERIAL No.
• Angular Velocity Sensor Sensitivity adjustment
• AWB standard data input & check, Color reproduction check
• Strobe adjustment
• Lens data carry
Regarding the PlayMemories Home
PlayMemories Home has been written in internal memory.
The SY-1001 board for service is supplied with PlayMemories Home pre-installed.
USB SERIAL No.
The set is shipped with a unique ID (USB Serial No.) written in it.
This ID has not been written in a new board for service, and therefore it must be entered after the board replacement.
Start the Adjust Manual in the Adjust Station and execute the “PRODUCT ID & USB SERIAL No. INPUT”.
Product ID
The unit is shipped after an ID (PRODUCT ID) unique to each model has been written.
This ID is not written to a new replacement board. Enter a unique ID after the board has been replaced.
Start the Adjust Manual in the Adjust Station and execute the “PRODUCT ID & USB SERIAL No. INPUT”.
Setting PRODUCT ID
No PRODUCT ID is set for a new replacement board.
Therefore, if the board is replaced with a new replacement board, a discrepancy with the user-registered PRODUCT ID provided by the customer 
may be generated.
After the board has been replaced with a new replacement board, start Adjust Manual from Adjust Station and execute “PRODUCT ID & USB SE-
RIAL No. INPUT”.
Lens Data Carry
When replacing the main board, read the QR code given on the Data Carry QR Seal attached to the JK-1002 Flexible Board.
Start the Adjust Manual and read the QR code using a QR code reader.
To read data from the main board, execute [Lens data carry] on the ADJUST tab of the Adjust Manual and read the previous data before the main board 
is replaced using [ORIGINAL DATA READ AND SAVE].
The read data is used for adjustment after replacement. When adjustment, execute [LOAD] from [Lens data carry] on the ADJUST tab of the Adjust 
Manual.
1-2.  NOTES ON REPLACING THE LENS
When replacing the lens, read the QR code given on the data sheet of the replacement 
lens for service.
Remove the Data Carry QR Seal and stick it to the JK-1002 Flexible Board. (For details, 
refer to “Assembly-1 Note on the IM Imager Unit and Lens Installation.”)
Start the Adjust Manual and read the QR code using a QR code reader.
The read data is used for adjustment after replacement. When adjustments, Select “Lens 
data carry” on the ADJUST tab of the Adjust Manual, and click the LOAD button to 
load the file.
Data carry QR seal
– ENGLISH –
1-3.  NOTES ON REMOVING/INSTALLING THE IMAGER BOARD
With the following features, this unit is likely to capture foreign particles.
• The imager sensor size is large.
• The space between the imager sensor and the lens is small.
Therefore, pay close attention to foreign particles.
1-4.  NOTES ON REPLACING THE LSV-1600A DEVICE AND THE IM IMAGER UNIT
1)   When replacing the LSV-1600A Device or the IM Imager Unit, read values from the IM Data Carry Seal and the Lens Data Carry QR Seal shown 
in the figure below, and then write down the read values.
 
Lens data carry QR seal
IM data carry seal
Lens data carry QR seal 
(Describing lens tilting amount)
IM data carry seal  
(Describing imager tilting amount) 
00000014
-14.77   10.30
1058300067
X -5.8 
Y
 +0.7
2)  Start “Shim Selection Tool Ver_[].[].exe.”
 
Enter each recorded value into “Shim Selection Tool Ver_[].[].exe” according to the figure below, and then click [OK].
Note: Download “Shim Selection Tool Ver_[].[].exe” from the TISS homepage.
 
Lens data carry QR seal
IM data carry seal
Enter the values provided on the seats attached to the lens block
and the rear tube. Then click the [OK] button.
1058300067
X -5.8  Y +0.7
00000014
-14.77   10.30
Page of 27