Read Sony DSC-QX30 Service Manual online
DSC-QX30
4-9
(2) 2 Group Frame Block Assy Replacing Method
Removal
1. Release the claw to detach the Z Retainer.
1. Release the claw to detach the Z Retainer.
Z Retainer
Claw
2. Disconnect the flexible board from the connector on the LF-2102 Flexible Board.
3. Remove the flexible board from the bosses and ribs of the Lens unit.
3. Remove the flexible board from the bosses and ribs of the Lens unit.
LF-2102 Flexible Board
Rib
Boss
Boss
Rib
Rib
Disconnect the flexible board.
Connector
Lens unit
4. Disconnect the LF-2102 Flexible Board from the connector on the Flexible Board.
5. Detach the sensor on the LF-2102 Flexible Board.
6. Remove the two screws to detach the Gear Block Assy.
5. Detach the sensor on the LF-2102 Flexible Board.
6. Remove the two screws to detach the Gear Block Assy.
Sensor
Hook
LF-2102
Flexible Board
Flexible Board
LF-2102
Flexible Board
Flexible Board
Connector
Gear Block Assy