DSC-P92 (serv.man3) - Sony Digital Camera Service Manual (repair manual). Page 4

Read Sony DSC-P92 (serv.man3) Service Manual online

— 4 —
DSC-P92
SELF-DIAGNOSIS FUNCTION
COVER
COVER
• NOTE FOR REPAIR
[Discharging of the FLASH unit’s charging capacitor]
The charging capacitor of the FLASH unit is charged up to the
maximum 300 V potential.
There is a danger of electric shock by this high voltage when the
capacitor is handled by hand.  The electric shock is caused by the
charged voltage which is kept without discharging when the main
power of the DSC-P92 is simply turned off.  Therefore, the remaining
voltage must be discharged as described below.
Preparing the Short Jig
To preparing the short jig. a small clip is attached to each end of a
resistor of 1 k
 /1 W (1-215-869-11)
Wrap insulating tape fully around the leads of the resistor to prevent
electrical shock.
1 k
/1 W
Wrap insulating tape.
Make sure that the flat cable and flexible board are not cracked of 
bent at the terminal.
Do not insert the cable insufficiently nor crookedly.
Cut and remove the part of gilt 
which comes off at the point.
(Take care that there are 
some pieces of gilt left inside)
When remove a connector, don't pull at wire of connector.
Be in danger of the snapping of a wire.
When installing a connector, don't press down at wire of connector.
Be in danger of the snapping of a wire.
Discharging the Capacitor
Short circuits between the positive and the negative terminals of
charged capacitor with the short jig about 10 seconds.
Capacitor
ST-82 BOARD
Shorting jig
(1k 
 / 1w)
Page of 7
Display