Read Sony DSC-P9 (serv.man2) Service Manual online
DSC-P9
5-29
19. CCD Black Defect Compensation
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: 6,
address: 55
address: 55
Measuring Instrument
Adjusting remote commander
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Note 2:
Check that there are no dust, no dirt and reflection of the
clear chart.
clear chart.
Note 3:
Any subject other than the clear chart should be in the
screen.
screen.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
camera system adjustment”.
(Refer to page 5-14)
2
E
65
Note down the data.
3
E
65
4C
Press PAUSE button.
4
6
2C
01
5
6
90
00
6
6
91
03
7
6
92
00
8
6
93
00
9
6
01
79
Press PAUSE button.
10
6
30
08
11
6
07
Check the data changes to
“01”.
“01”.
12
Wait for 4 seconds.
13
6
01
8D
Press PAUSE button.
14
6
02
Check the data changes to
“01”.
“01”.
15
6
55
Check the data.
00 to 14 : Normal
15 to FF : Defective
(Note 4)
00 to 14 : Normal
15 to FF : Defective
(Note 4)
16
6
01
00
Press PAUSE button.
17
E
65
5A
Press PAUSE button.
18
6
01
89
Press PAUSE button.
19
6
02
Check the data changes to
“01”.
“01”.
20
6
55
Check the data.
00: Normal
01 to FF: Defective
00: Normal
01 to FF: Defective
Note 4:
If the data is “00” at the check in this adjustment method
order #15, skip the orders from #16 to #20 , and go for-
ward to “Processing after Completing Adjustment.
order #15, skip the orders from #16 to #20 , and go for-
ward to “Processing after Completing Adjustment.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
30
00
4
6
91
00
5
E
65
Set data noted down at step
2, and press PAUSE button.
2, and press PAUSE button.
6
Release the data setting
performed at step 1.
(Refer to page 5-14)
performed at step 1.
(Refer to page 5-14)
Click on the first or last page to see other DSC-P9 (serv.man2) service manuals if exist.