Read Sony DSC-P8 (serv.man4) Service Manual online
DSC-P8
6-24
13. CCD White Defect Compensation
Mode
CAMERA
Subject
Not required
Measurement Point
Data of page: 60, address: 55
Note:
Check that the data of page: 60, address: 02 is “00”. If not,
press the RESET switch using a thin and long pin.
Adjusting method:
Order Page Address
Data
Procedure
1
Perfom “Data setting
during camera sysem
adjustment”.
(Refer to page 6-13)
during camera sysem
adjustment”.
(Refer to page 6-13)
2
7D
64
1E
[Set]
3
7D
69
0D
[Set]
4
60
01
8B
[Write]
5
60
02
[Read]
Check the data changes
to “01”.
to “01”.
6
60
55
[Read]
Check the data.
00 to 7F: Normal
80 to FF: Defective
00 to 7F: Normal
80 to FF: Defective
7
60
01
00
[Write]
8
7D
64
0F
[Set]
9
7D
69
60
[Set]
10
60
01
87
[Write]
11
60
02
[Read]
Check the data changes
to “01”.
to “01”.
12
60
55
[Read]
Check the data.
00 : Normal
01 to FF: Defective
00 : Normal
01 to FF: Defective
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00
[Write]
2
7D
64
[Read]
3
7D
69
[Read]
4
Release “Data settig
during camera system
adjustment”
(Refer to page 6-13)
during camera system
adjustment”
(Refer to page 6-13)
14. CCD Black Defect Compensation
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Data of page: 60, address: 55
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
not, press the RESET switch using a thin and long pin.
Note 2:
Check that there are no dust, no dirt and reflection of the
clear chart.
clear chart.
Note 3:
Any subject other than the clear chart should be in the
screen.
screen.
Adjusting method:
Order Page Address
Data
Procedure
1
Perfom “Data setting
during camera sysem
adjustment”.
(Refer to page 6-13)
during camera sysem
adjustment”.
(Refer to page 6-13)
2
7D
65
4C
[Set]
3
60
90
00
[Set]
4
60
91
03
[Set]
5
60
92
00
[Set]
6
60
93
00
[Set]
7
60
01
79
[Write]
8
60
30
08
[Set]
9
60
07
[Read]
Check the data changes
to “01”.
to “01”.
10
60
01
8D
[Write]
11
60
02
[Read]
Check the data changes
to “01”.
to “01”.
12
60
55
[Read]
Check the data.
00: Proceed to “Process-
ing after Completing
Adjustment”
00 to 0A : Normal
0B to FF : Defective
00: Proceed to “Process-
ing after Completing
Adjustment”
00 to 0A : Normal
0B to FF : Defective
13
60
01
00
[Write]
14
7D
65
5A
[Set]
15
60
01
89
[Write]
16
60
02
[Read]
Check the data changes
to “01”.
to “01”.
17
60
55
[Read]
Check the data.
00 : Normal
01 to FF : Defective
00 : Normal
01 to FF : Defective
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00
[Write]
2
60
30
00
[Set]
3
7D
65
[Read]
4
Release “Data settig
during camera system
adjustment”
(Refer to page 6-13)
during camera system
adjustment”
(Refer to page 6-13)
Click on the first or last page to see other DSC-P8 (serv.man4) service manuals if exist.