DSC-P8 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 19

Read Sony DSC-P8 (serv.man4) Service Manual online

DSC-P8
6-17
5. Light Value Adjustment
Adjust the standar light value.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Data of page: 10, address: 0C and
0D (2byte data) (Note 2)
Data of page: 6F, address: 65
Adjustment Page
6F
Adjustment Address
65 to 67
Specified value 1
0FE0 to 1020
Specified value 2
30 to 44
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
Note 2:
2byte data is upper 1byte data and lower 1 byte data.
                XX XX
                                     Lower 1byte data (Page: 10, adderss: 0D)
Upper 1byte data (Page: 10, adderss: 0C)
Adjusting method:
Order Page Address
Data
Procedure
1
Perfom “Data setting
during camera sysem
adjustment”.
(Refer to page 6-13)
2
Perfom “Picture frame
setting”
(Refer to page 6-14)
3
60
01
0D 
[Write]
(Note 3)
4
60
02
[Read]
Check the data changes
to “01”.
5
10
0C
[Read]
Read the data
(Upper 1byte).
6
10
0D
[Read]
Read the data
(Lower 1byte).
7
Check that the 2byte
data (Note 2) satisfied
the specified value 1.
8
6F
65
[Read]
Check that the data
satisfied the specified
value 2.
Note 3:
The adjustment data will be automatically input to page:
6F, address: 65 to 67.
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data settig
during camera system
adjustment”
(Refer to page 6-13)
4.
Mechanical Shutter Adjustment
Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Data of page: 6F, address: 6B
Adjustment Page
6F
Adjustment Address
6B to 6D, B8 to D7
Specified value
00
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
Adjusting method:
Order Page Address
Data
Procedure
1
Perfom “Data setting
during camera sysem
adjustment”.
(Refer to page 6-13)
2
Perfom “Picture frame
setting”
(Refer to page 6-14)
3
60
01
AD 
[Write]
(Note 2)
4
60
02
[Read]
Check the data changes
to “01”.
5
6F
6B
[Read]
Check that the data
satisfied the specified
value.
Note 2:
The adjustment data will be automatically input to page:
6F, address: 6B to 6D and 8B to D7.
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data settig
during camera system
adjustment”
(Refer to page 6-13)
Page of 37
Display