Read Sony DSC-P8 (serv.man4) Service Manual online
DSC-P8
6-17
5. Light Value Adjustment
Adjust the standar light value.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Data of page: 10, address: 0C and
0D (2byte data) (Note 2)
0D (2byte data) (Note 2)
Data of page: 6F, address: 65
Adjustment Page
6F
Adjustment Address
65 to 67
Specified value 1
0FE0 to 1020
Specified value 2
30 to 44
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
not, press the RESET switch using a thin and long pin.
Note 2:
2byte data is upper 1byte data and lower 1 byte data.
XX XX
Lower 1byte data (Page: 10, adderss: 0D)
Lower 1byte data (Page: 10, adderss: 0D)
Upper 1byte data (Page: 10, adderss: 0C)
Adjusting method:
Order Page Address
Data
Procedure
1
Perfom “Data setting
during camera sysem
adjustment”.
(Refer to page 6-13)
during camera sysem
adjustment”.
(Refer to page 6-13)
2
Perfom “Picture frame
setting”
(Refer to page 6-14)
setting”
(Refer to page 6-14)
3
60
01
0D
[Write]
(Note 3)
4
60
02
[Read]
Check the data changes
to “01”.
to “01”.
5
10
0C
[Read]
Read the data
(Upper 1byte).
(Upper 1byte).
6
10
0D
[Read]
Read the data
(Lower 1byte).
(Lower 1byte).
7
Check that the 2byte
data (Note 2) satisfied
the specified value 1.
data (Note 2) satisfied
the specified value 1.
8
6F
65
[Read]
Check that the data
satisfied the specified
value 2.
satisfied the specified
value 2.
Note 3:
The adjustment data will be automatically input to page:
6F, address: 65 to 67.
6F, address: 65 to 67.
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00
[Write]
2
Release “Data settig
during camera system
adjustment”
(Refer to page 6-13)
during camera system
adjustment”
(Refer to page 6-13)
4.
Mechanical Shutter Adjustment
Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
pensate the exposure.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Data of page: 6F, address: 6B
Adjustment Page
6F
Adjustment Address
6B to 6D, B8 to D7
Specified value
00
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
not, press the RESET switch using a thin and long pin.
Adjusting method:
Order Page Address
Data
Procedure
1
Perfom “Data setting
during camera sysem
adjustment”.
(Refer to page 6-13)
during camera sysem
adjustment”.
(Refer to page 6-13)
2
Perfom “Picture frame
setting”
(Refer to page 6-14)
setting”
(Refer to page 6-14)
3
60
01
AD
[Write]
(Note 2)
4
60
02
[Read]
Check the data changes
to “01”.
to “01”.
5
6F
6B
[Read]
Check that the data
satisfied the specified
value.
satisfied the specified
value.
Note 2:
The adjustment data will be automatically input to page:
6F, address: 6B to 6D and 8B to D7.
6F, address: 6B to 6D and 8B to D7.
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00
[Write]
2
Release “Data settig
during camera system
adjustment”
(Refer to page 6-13)
during camera system
adjustment”
(Refer to page 6-13)