9. Auto White Balance 3200K Check
Check that the white balance standard data at 3200K are inputted
properly.
properly.
Mode
STILL (
)
Subject
Clear chart
(Standard picture frame)
(Standard picture frame)
Measurement Point
Data of page: 10, address: 08, 09, 0A,
0B, 59, 5B
0B, 59, 5B
Measuring Instrument
Data of page: 6F, address: 74, 76, B5
Specified value 1
R ratio = 3F00 to 4100
Specified value 2
B ratio = 3F00 to 4100
Specified value 3
R-Y data = 7A to 86
Specified value 4
B-Y data = 7A to 86
Specified value 5
R/G data = 20 to 60
Specified value 6
B/G data = 10 to 40
Specified value 7
00
Note:
If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.
01, and write data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
CAMERA setting (Menu setting) ................................ AUTO
CAMERA setting (Menu setting) ................................ AUTO
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting during
Camera System Adjustments” is
performed.
Camera System Adjustments” is
performed.
2
Check the picture frame.
If deviated, perform “4. Picture
Frame Setting”.
If deviated, perform “4. Picture
Frame Setting”.
3
00
01
01
Set the data.
4
6F
B5
FF
Write the data.
3200K standard data Check (1)
5
60
37
0D
Write the data.
6
60
01
11
Write the data.
7
Wait for 1 sec.
8
60
38
Read the data, and check it is “01”.
9
60
01
C1
Write the data.
10
Wait for 1 sec.
11
60
02
Read the data, and check it is “01”.
12
10
08
Read the data, and this data is
named D
named D
08
.
13
10
09
Read the data, and this data is
named D
named D
09
.
14
Calculate R ratio using the
following equation
(Hexadecimal calculation)
R ratio = D
following equation
(Hexadecimal calculation)
R ratio = D
08
×
100 + D
09
15
Check that R ratio satisfies the
specified value1.
specified value1.
16
10
0A
Read the data, and this data is
named D
named D
0A
.
17
10
0B
Read the data, and this data is
named D
named D
0B
.
Order Page Address Data
Procedure
18
Calculate B ratio using the
following equation
(Hexadecimal calculation)
B ratio = D
following equation
(Hexadecimal calculation)
B ratio = D
0A
×
100 + D
0B
19
Check that B ratio satisfies the
specified value2.
specified value2.
20
10
59
Read the data (R-Y data), and check
it satisfies the specified value3.
it satisfies the specified value3.
21
10
5B
Read the data (B-Y data), and check
it satisfies the specified value4.
it satisfies the specified value4.
22
60
01
00
Write the data.
3200K standard data Check (2)
23
6F
74
Read the data (R/G data), and check
it satisfies the specified value 5.
it satisfies the specified value 5.
24
6F
76
Read the data (B/G data), and check
it satisfies the specified value 6.
it satisfies the specified value 6.
25
6F
B5
Read the data, and check it
satisfies the specified value 7.
satisfies the specified value 7.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
37
00
Write the data.
2
60
01
00
Write the data.
3
Perform next adjustments.
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)