DSC-P71, DSC-P71M - Sony Digital Camera Service Manual (repair manual). Page 113

Read Sony DSC-P71 / DSC-P71M Service Manual online

5-8
DSC-P71/P71M
3.
A Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing the A Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of A Page Data”)
Address
Initial value
Remark
00, 01
Fixed data-1 (Initialized data)
02
00
Test mode
03 to 61
Fixed data-1 (Initialized data)
62
63
Fixed data-2
64 to 7F
Fixed data-1 (Initialized data)
80
8E
Backlight current adj. (BL L)
81
36
Backlight current adj. (BL H)
82
5E
VCO adj. (NTSC)
83
7C
VCO adj. (PAL)
84
A9
V-COM DC adj.
85
9B
D Range adj.
86
0A
Black limit adj.
87
3A
Psig Gray adj./V-COM adj.
88
90
89
83
White balance adj.
8A
4C
Contrast adj.
8B
48
Center voltage adj.
8C
8D
8E
Fixed data-2
8F
90 to 9F
Fixed data-1 (Initialized data)
A0
80
Composite video level adj.
A1, A2
Fixed data-1 (Initialized data)
A3
A4
Fixed data-2
A5 to A8
Fixed data-1 (Initialized data)
A9
Fixed data-2
AA to FF
Fixed data-1 (Initialized data)
4.
D Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing the D Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of D Page Data”)
Address
Initial value
Remark
10 to1F
Fixed data-1 (Initialized data)
20
Not used
21
00
Test mode
22 to 36
Fixed data-1 (Initialized data)
37 to 3F
Not used
40 to 5A
Fixed data-1 (Initialized data)
5B
Not used
5C to 73
Fixed data-1 (Initialized data)
1-2.
INITIALIZATION OF A, B, D, E, F, 7, 9 PAGE
DATA
1-2-1.
Initialization of A, D Page Data
1.
Initializing A, D Page Data
Note:
If the A, D page data has been initialized, the following
adjustments need to be performed again.
1) Modification of A, D page data
2) Video system adjustments
3) LCD system adjustments
4) System control system adjustments
Adjsuting page
A
Adjsuting Address
00 to FF
Adjusting page
D
Adjusting Address
10 to 73
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
2
4
03
06
3
4
00
2D
4
4
01
2D
Press PAUSE button.
5
4
02
Check the data changes to “01”.
6
Perform “Modification of
A, D page Data”.
2.
Modification of A, D Page Data
If the A, D page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camera may not operate.
3)
When changing the data, press the PAUSE button of the
adjusting remote commander each time when setting new data
to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of A, D Page Data:
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
Page of 127
Display

Click on the first or last page to see other DSC-P71 / DSC-P71M service manuals if exist.