DSC-P7 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 38

Read Sony DSC-P7 (serv.man4) Service Manual online

DSC-P7
6-36
2H
A
Pedestal
10 steps peak
A: Between the pedestal and 10 steps peak
5. Contrast Adjustment (SW-368 Board)
Set the level of the VIDEO signal for driving the LCD to the speci-
fied value.
If deviated, the LCD screen image will be blackish or saturated
(whitish).
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN706 on SY-77 board
(VG)
External trigger: Pin 8 of CN706
on SY-77 board (PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
A
Adjustment Address
8A
Specified Value
A = 2.50 
±
 0.05 Vp-p
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
A
02
03
Press PAUSE button
3
4
F1
03
Change the data and set the
4
A
8A
voltage (A) to the specified
value. (Note)
5
A
8A
Press PAUSE button.
Note 1:
Adjust it between data 00 and 7F.
Note 2:
After adjustment, check that Bright adjusted value is
within the specification.
When it is not, retry Bright adjustment and perform con-
trast adjustment.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
A
02
00
Press PAUSE button
2
4
F1
00
3
0
01
00
Fig. 6-1-21
6. VG Center Adjustment (SW-368 Board)
Set the center of VG signal for driving the LCD to the specified
value.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN706 on SY-77 board
(VG)
Measuring Instrument
Digital voltmeter
Adjustment Page
A
Adjustment Address
8B
Specified Value
A = 7.00 
±
 0.05 Vp-p
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
A
02
03
Press PAUSE button
3
4
F1
02
Change the data and set the
4
A
8B
DC voltage (A) to the specified
 value. (Note)
5
A
8B
Press PAUSE button.
Note:
Adjust it between data 00 and 7F.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
A
02
00
Press PAUSE button
2
4
F1
00
3
0
01
00
Page of 45