6-8
DSC-P52
COVER
COVER
1-2.
INITIALIZATION OF 0E, 2F, 4F, 6F PAGE
DATA
1-2-1.
INITIALIZATION OF 2F PAGE DATA
1. Initializing the 2F Page Data
Adjusting page
2F
Adjusting Address
00 to 7F
Initializing Method:
1)
Select page:00, address:01, and set data:01.
2)
Click [Page Edit] on the SEUS screen to display the SEUS
PAGE EDIT screen.
3)
Click [Page] to display the INPUT PAGE screen, and input
“2F”.
4)
Click [Preset Data Read] on the SEUS PAGE EDIT screen to
display the INPUT SETID screen.
5)
Input “03” and click [OK] to read the preset data.
6)
On the SEUS PAGE EDIT screen, change the data of the “Fixed
data-2” address shown in the following table by manual input.
Note: New data for changing are not shown in the table because they
are different in destination. When changing the data, copy the
data built in the same model. If copy the data built in the different
model, the camera may not operate.
7)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
8)
Click [Write] to write the initializing data to the EEPROM of
the camera.
9)
Click [Close] to close the SEUS PAGE EDIT screen.
Processing after Completing Initializing of 2F Page data
Order Page Address Data
Procedure
1
20
00
29
Write the data.
2
20
01
29
Write the data.
3
Check “Receive Paket Error” is
displayed on the SEUS screen.
4
Turn on the power.
5
Click [Connect] on the SEUS
screen.
Address
Remark
Initial value
Address
Remark
Initial value
00 to 20
21
22 to 7F
00
Test mode
Fixed data-1
2. 2F Page Table
Note: Fixed data-1: Initialized data. (Refer to “1. Initializing the 2F Page
Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 2F Page
Data”.)
Table. 6-1-2.
Page of 43
Display