DSC-P5 (serv.man3) - Sony Digital Camera Service Manual (repair manual). Page 6

Read Sony DSC-P5 (serv.man3) Service Manual online

– 6 –
DSC-P5
Display Code
  C:32:ss
  C:13:ss
  E:61:ss
  E:91:ss
Countermeasure
Turn the power off and on again.
Format the “Memory stick”.
Insert a new “Memory Stick”.
Checking of lens drive circuit.
Cause
Trouble with hardware.
Unformatted memory stick is inserted.
Memory stick is broken.
When failed in the focus and zoom
initialization.
Abnormality when flash is being
charged.
Checking of flash unit or replacement
of flash unit.
Caution Display During Error
SYSTEM ERROR
FORMAT ERROR
MEMORY STICK ERROR
[Description on Self-diagnosis Display]
Self-diagnosis display
• C: ss: ss
You can reverse the camera mal-
function yourself. (However, con-
tact your Sony dealer or local
authorized Sony service facility
when you cannot recover from
the camera malfunction.)
• E: ss: ss
Contact your Sony dealer or lo-
cal authorized Sony service facil-
ity.
[Precaution on Replacing the Lens Block or the SY-69
Board]
The DSC-P5 uses the position sensor to detect the zoom position.
Accordingly, the zoom position will vary if the position data
changes due to the replacement of the lens block or the SY-69
board, thus causing the lens block to collide against the mecha-
nism end when the power is turned off.
Though the position data is calibrated at the “Flange Back Adjust-
ment”, add the following work when making an adjustment at the
replacement of lens block to prevent a collision of lens block.
When Replacing the Lens Block
1) With current lens block assembled, turn the power on, and set
the bit value of Bit0 on Page:9, Address:65 to “0” using the
adjusting remote commander, then turn the power off.
2) Replace the lens block with a new one, turn the power on, and
perform the “Flange Back Adjustment”.
Thus, new position data will be written.
3) After the “Flange Back Adjustment”, return the bit value of
Bit0 on Page:9, Address:65 to “1” using the adjusting remote
commander.
When Replacing the SY-69 Board
1) Replace the SY-69 board with a new one, set the mode dial to
“PLAY”, turn the power on, and set the bit value of Bit0 on
Page:9, Address:65 to “0” using the adjusting remote com-
mander, then turn the power off.
2) Set the mode dial to “CAMERA”, turn the power on, and per-
form the “Flange Back Adjustment”.
Thus, new position data will be written.
3) After the “Flange Back Adjustment”, return the bit value of
Bit0 on Page:9, Address:65 to “1” using the adjusting remote
commander.
Page of 100