SYSTEM CONTROL SYSTEM ADJUSTMENTS
1. Battery Down Adjustment
Set the battery end voltage.
If the voltage is incorrect, the life of battery will shorten.
The image at the battery end will also be rough.
If the voltage is incorrect, the life of battery will shorten.
The image at the battery end will also be rough.
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Displayed data of page: 2,
address: 9A
address: 9A
Measuring Instrument
Adjusting remote commander
Adjustment Page
D
Adjustment Address
90 to 94
Connection:
1) Connect the regulated power supply and the digital voltmeter
1) Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 5-1-27.
Preparations before adjustment:
1) Adjust the output voltage of the regulated power supply so
1) Adjust the output voltage of the regulated power supply so
that the digital voltmeter display is 4.2
±
0.1 Vdc.
2) Turn off the power supply.
3) Set the HOLD switch of the adjusting remote commander to
3) Set the HOLD switch of the adjusting remote commander to
“HOLD” (SERVICE position).
4) Turn on the power supply.
5) Insert the memory stick to the unit, and set the CAMERA mode.
5) Insert the memory stick to the unit, and set the CAMERA mode.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
2C
01
Decrease the output voltage
3
of the regulated power supply
so that digital voltmeter display
is 3.20
so that digital voltmeter display
is 3.20
±
0.01 Vdc.
4
2
9A
Read the data, and this data
is named Dref.
is named Dref.
5
D
90
Dref
Press PAUSE button.
6
Convert Dref to decimal notati
on and obtain Dref’. (Note)
on and obtain Dref’. (Note)
Calculate D
91
’, D
92
’, D
93
’
and D
94
’ using following
equations(decimal calculation)
7
D
91
’=Dref’+6
D
92
’=Dref’+23
D
93
’=Dref’+44
D
94
’=Dref’+55
Convert D
91
’, D
92
’, D
93
’ and
8
D
94
’ to a hexadecimal number,
and obtain D
91
, D
92
, D
93
and
D
94
(Note)
9
D
91
D
91
Press PAUSE button.
10
D
92
D
92
Press PAUSE button.
11
D
93
D
93
Press PAUSE button.
12
D
94
D
94
Press PAUSE button.
Note:
Refer to table 5-2-2. “Hexadecimal-decimal conversion
table”
table”
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
2C
00
2
0
01
00
1
18
Regulated power supply
(6.0 to 7.2 Vdc)
(6.0 to 7.2 Vdc)
CPC-9jig
(J-6082-393-C)
(J-6082-393-C)
Adjusting remote
commander
commander
Regulated power supply
(3.20
(3.20
±
0.01 Vdc)
Digital voltmeter
1
18
Fig. 5-1-27