14. CCD White Defect Compensation
Mode
CAMERA
Subject
Not required
Measurement Point
Displayed data of page: 6,
address: 55
address: 55
Measuring Instrument
Adjusting remote commander
Adjustment Page
7
Adjustment Address
88 to FF
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Note 2:
The “CCD White Defect Compensation” should be made
when the set warms up at certain duration after the power
was turned on, as it is affected with the temperature.
when the set warms up at certain duration after the power
was turned on, as it is affected with the temperature.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-15)
camera system adjustments”.
(Refer to page 5-15)
3
F
DE
1E
Press PAUSE button.
4
F
E3
13
Press PAUSE button.
5
6
01
8B
Press PAUSE button. (Note 3)
6
6
02
Check the data changes to “01”.
7
6
55
Check the data.
00 to 7F: Normal
80 to FF: Defective
00 to 7F: Normal
80 to FF: Defective
8
6
01
00
Press PAUSE button.
9
F
DE
0F
Press PAUSE button.
10
F
E3
60
Press PAUSE button.
11
6
01
87
Press PAUSE button.
12
6
02
Check the data changes to “01”.
13
6
55
Check the data is “00”.
Note 3:
The adjustment data will be automatically input to
page: 7, address: 88 to FF.
page: 7, address: 88 to FF.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 2 . (Refer
to page 5-15)
performed at step 2 . (Refer
to page 5-15)
3
0
01
00