DSC-P150 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 27

Read Sony DSC-P150 (serv.man4) Service Manual online

6-25
DSC-P150
1-5-3.
Adjusting Method
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during LCD Adj.
2. VCO Adj.
3. Contrast Adj.
4. V-COM Adj.
5. White Balance Adj.
6. Release of Data Setting during LCD Adj.
[Adjusting method]
1) Click the 
[LCD Adjustment Start]
 button.
2) The Automatic Adjustment Program executes the items from
“1. Data Setting during LCD Adj.” to “3. Contrast Adj.”.
3) Upon successful completion of the “3. Contrast Adj.”, the fol-
lowing message is displayed during execution in “4. V-COM
Adj.”. On the SEUS screen, operate the UP/DOWN key so
that the brightness of portions A and B on the LCD panel is
equal. After the adjustment, click the 
[OK]
 button.
Fig. 6-1-59
4) Upon completion of “4. V-COM Adj.”, “5. White Balance Adj.”
is executed. The following message is displayed, and then check
that LCD screen is not colored.
If colored, change the data of page: 8F, address: 28 and 2A on
the SEUS Operation screen to adjust so that the LCD screen is
not colored.
Fig. 6-1-60
5) If the 
[OK]
 button is clicked, “6. Release of Data Setting dur-
ing LCD Adj.” will be executed.
Fig. 6-1-61
SEUS operation screen
Fig. 6-1-62
Check on the LCD screen (V-COM Adj.)
Fig. 6-1-63
UP/DOWN key
A
A
A
A
B
B
B
B
Page of 35
Display

Click on the first or last page to see other DSC-P150 (serv.man4) service manuals if exist.