DSC-P100, DSC-P120 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 10

Read Sony DSC-P100 / DSC-P120 (serv.man2) Service Manual online

2-6
DSC-P100/P120
2-3-2. REMOVE OLD BARRIER ASSY
1
Remove two screws.
*
Discard the removed screws.
2
Remove the Barrier Assy.
*
Discard the removed Barrier Assy.
*
After removing the Barrier Assy, if the “G1 Dust-Proof Ring” was removed, it must be returned to the home position.
In returning the ring, adjust the location of a projection to the lens direction.
This is an important part to prevent the dust and light from coming in.
*
After removing the Barrier Assy, take extreme care not to drop dust or foreign substances in the lens barrel.
2-3-3. INSTALL NEW BARRIER ASSY
1
Install new Barrier Assy by paying attention to the projection of the Barrier Assy in relation to the position shown in the under figure.
2
Tighten two screws.
*
Tightening torque = 0.5 kgf
1
1
2
Projection
2
2
1
Page of 45