Read Sony DSC-P10 / DSC-P12 (serv.man4) Service Manual online
DSC-P10/P12
6-5
Fig. 6-1-5
1 k
Ω
/1 W
Wrap insulating tape.
Fig. 6-1-4
R:1 k
Ω
/1 W
(Part code:
1-215-869-11)
1-215-869-11)
Capacitor
ST
-81
1-1-3.
Discharging of the Flashlight Power Supply
The capacitor which is used as power supply of flashlight is charged
with 200 V to 300 V voltage. Discharge this voltage before start-
ing adjustments in order to protect service engineers from electric
shock during adjustment.
with 200 V to 300 V voltage. Discharge this voltage before start-
ing adjustments in order to protect service engineers from electric
shock during adjustment.
Discharge procedure
1. Press the FLASH button (SW-386 board S004 (CONTROL
1. Press the FLASH button (SW-386 board S004 (CONTROL
UP)) and set the NO FLASH mode.
2. Fabricate the discharging jig as shown in Fig. 6-1-5 locally by
yourself. Connect the discharging jig to the positive (+) and
negative (–) terminal of the flash voltage charge capacitor. Al-
low ten seconds to discharge the voltage.
negative (–) terminal of the flash voltage charge capacitor. Al-
low ten seconds to discharge the voltage.
Click on the first or last page to see other DSC-P10 / DSC-P12 (serv.man4) service manuals if exist.