DSC-N2 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 26

Read Sony DSC-N2 (serv.man4) Service Manual online

6-24
DSC-N2_ADJ
6) Upon successful completion of all item the LCD Adjustment,
the following message is displayed. Click the [OK] button.
Fig. 6-1-49
SEUS operation screen
Fig. 6-1-50
Check on the LCD screen (V-COM Adj.)
Fig. 6-1-51
1-5-3.
Adjusting Method
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during LCD Adj.
2. V-COM Adj.
3. White Balance Adj.
4. Release of Data Setting during LCD Adj.
[Adjusting method]
1) Click the [Start] button of the LCD Adjustment.
2) The Automatic Adjustment Program executes “1. Data Setting
during LCD Adj.”.
3) Upon successful completion of the “1. Data Setting during LCD
Adj.”, the following message is displayed during execution in
“2. V-COM Adj.”. On the SEUS screen, operate the UP/DOWN
key so that the brightness of portions A and B on the LCD
panel is equal. After the adjustment, click the [OK] button.
Fig. 6-1-47
4) Upon completion of “2. V-COM Adj.”, the following screen is
displayed during the execution of “3. White Balance Adj.”.
Check that the LCD screen is not colored. If colored, using the
[Up]/[Down] button on the screen, adjust so that the LCD screen
is not colored. After the adjustment, click the [End] button in
the screen.
Fig. 6-1-48
5) If the [End] button is clicked, “4. Release of Data Setting dur-
ing LCD Adj.” will be executed.
UP/DOWN key
A
B
Page of 34
Display