Read Sony DSC-N1 (serv.man4) Service Manual online
6-21
DSC-N1_ADJ
6.
AWB 3200K-5800K Standard Data Input
[Adjustment method]
1) Start the Color Adjustment Program (N1ColorAdjustment.exe).
2) Click the
1) Start the Color Adjustment Program (N1ColorAdjustment.exe).
2) Click the
[Connect]
button to set the camera to the adjust-
ment mode.
Fig. 6-1-35
3) Adjust the mode switch of the camera to “CAMERA” and set
MACRO mode. Shoot the 9 colors chart with the zoom at WIDE
end.
end.
4) Adjust the camera direction and distance to set the picture
frame. (Refer to 3. Picture Frame Setting)
5) Click the
[AWB 3200-5800K Standard Data Input]
button.
Fig. 6-1-36
6) A picture captured by the camera is displayed on the screen,
and the adjustment and checking are performed.
Fig. 6-1-37
Note:
If the following message is displayed, the picture frame
setting is faulty. Check the picture frame, and then perform
readjustment.
setting is faulty. Check the picture frame, and then perform
readjustment.
Fig. 6-1-38
7) Upon successful completion of the adjustment, the following
message is displayed. Click the
[OK]
button.
Fig. 6-1-39
Click on the first or last page to see other DSC-N1 (serv.man4) service manuals if exist.