DSC-HX400 - Sony Digital Camera Service Manual (repair manual). Page 17

Read Sony DSC-HX400 Service Manual online

DSC-HX400/HX400V
3-1
3. SERVICE  NOTE
3-1.  PRECAUTION ON REPLACING THE SY-1034 BOARD
DESTINATION DATA
When you replace to a board for service, the written destination data of the board for service also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATION DATA WRITE”.
RESTORE DATA
When you replace to the repairing board, get the data from the former one.
Start the Adjust Manual in the Adjust Station and perform “RESTORE DATA” to get the data. 
The data getting for this model is as follows.
•  PRODUCT ID & USB SERIAL No.
•  AWB adj
USB Serial No. and Product ID
The unit is shipped after an ID (USB Serial No.) unique to each unit and an ID (Product ID) unique to each model have been written.
These IDs have not been written in a new board for service, and therefore they must be entered after the board replacement.
After the board has been replaced with a board for service, start the Adjust Manual in the Adjust Station and execute the “PRODUCT ID & 
USB SERIAL No. INPUT” and enter these IDs.
Note: 
A newly entered Product ID is not always equal to the ID before board replacement. If the new ID differs from the previous ID, it may cause a difference 
from the ID registered by the customer.
Update of MAC Address
When a board that contains Wi-Fi has been replaced or when replacing a board that contains the main IC (CPU), the IC’s unique number (MAC 
address) must be reloaded.
Perform the following procedure to reload the IC’s unique number (MAC address).
Note:  Perform the following operations after all work has been done.
1.  Download the latest-version Adjust Manual.
2.  Install the downloaded Adjust Manual.
3.  Start the Adjust Manual, and execute “Wireless LAN Setting (MAC Address)” on the ADJUST tab.
4.  Perform the following operations for the unit to initialize of SSID/PW.
 
 → [  (Wireless)] → [SSID/PW Reset] → [OK]
Applicable parts
•  SY-1034 BOARD, COMPLETE (SERVICE)
Note:  The LOAD AND WRITE function in ADJUSTMENT DATA BACKUP on the DATA tab in the Adjust manual overwrites all data of the unit.
 
Therefore, the MAC address updated during the above procedure is also overwritten.
After the replacement and repair, the MAC address is changed, and thus the re-setting for connection devices is required. Accordingly, download 
the Flyer of WLAN Reset (Flyer of WLAN Reset_9834752[][].pdf) and print out it, and attach it to the set when returning the set to customer.
Angular Velocity Sensor
When you replace to the repairing board, write down the sensitivity displayed on the angular velocity sensor (SE7701).
Start the Adjust Manual in the Adjust Station and execute the “Angular velocity sensor sensitivity adj”.
P: PITCH sensor sensitivity
Y: YAW sensor sensitivity
Type A:
Type B:
Y P
Y P
SE7701
(PITCH/YAW)
SY-1034 BOARD (SIDE A)
Note: The sensor sensitivity of SE7701 of SY-1034 board is written only repair parts.
– ENGLISH –
Page of 50
Display