DSC-HX300 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 16

Read Sony DSC-HX300 (serv.man2) Service Manual online

DSC-HX300_L2
1-13
(21)  Remove the five screws to detach the Shafts Retainer Assy and the 2nd Assy.
 
2nd Assy,
Shafts Retainer Assy
(22)  Detach the 2nd Assy from the Shafts Retainer Assy.
 
Shafts Retainer Assy
2nd Assy
Installation
(1)  Attach the 2nd Assy to the Shafts Retainer Assy.
 
Shafts Retainer Assy
2nd Assy
(2)  Match the groove with the hole and attach the Straight Tube to the Cam Tube Assy.
Cam Tube Assy
Straight Tube
Match the groove with the hole
Hole
Groove
(3)  Match the boss with the groove, attach the Shafts Retainer Assy and the 2nd Assy to the Straight Tube, and then tighten five screws.
 
2nd Assy,
Shafts Retainer Assy
Straight Tube
Groove
Boss