DSC-HX10, DSC-HX10V (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 7

Read Sony DSC-HX10 / DSC-HX10V (serv.man2) Service Manual online

DSC-HX10/HX10V_L2
1-4
– ENGLISH –
1-6. SELF-DIAGNOSIS FUNCTION
1-6-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis func-
tion starts working, and displays on the LCD screen what to do.
Details of the self-diagnosis functions are provided in the Instruction 
manual.
1-6-2. Self-diagnosis Display
When problems occur while the unit is operating, the LCD screen shows 
a 4-digit display consisting of an alphabet and numbers, which blinks at 
3.2 Hz. This 5-character display indicates the “repaired by:”, “block” in 
which the problem occurred, and “detailed code” of the problem.
0 0
3 2
C
Repaired by:
Refer to “1-6-3. Self-diagnosis Code Table”.
Indicates the appropriate
step to be taken.
E.g.
13 ....Format the “memory card”.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2 Hz
C : Corrected by customer
E : Corrected by service
engineer
LCD screen
1-6-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
1
3
0
1
The internal memory has experienced a 
media error.
Turn the power off and on again.
The internal memory has experienced a 
format error.
Format the internal memory.
Memory card is unformatted.
Format the memory card.
Memory card is broken.
Insert a new memory card.
Memory card type error.
Insert a supported memory card.
The camera cannot read or write data on 
the memory card.
Turn the power off and on again, or taking out and inserting the memory 
card several times.
C
3
2
0
1
Trouble with hardware.
Turn the power off and on again.
E
4
1
0
0
Abnormality of network control.
Turn power off and turn power on again.
E
4
1
0
1
Abnormality of network control device.
Turn power off and turn power on again.
E
6
1
0
0
Difficult to adjust focus.
(Cannot initialize focus)
Retry turn the power on by the power switch. If it does not recover, check 
the focus reset sensor of lens block (pin wj, wl of CN403 on the SY-323 
board). If it is OK, check the focus motor drive IC (IC401 on the SY-323 
board).
E
6
1
1
0
Zoom operations fault.
(Cannot initialize zoom lens.)
Retry turn the power on by the power switch. Check the zoom reset sensor 
of lens block (pin rg of CN403 on the SY-323 board) when zooming is 
performed when the zoom button is operated. If it is OK, check the zoom 
motor drive IC (IC401 on the SY-323 board).
E
6
1
3
0
Reset position detection error on the step-
per iris initializing.
Turn power off and turn power on again.
E
6
2
0
2
Abnormality of IC for steadyshot.
Check or replacement of the IC for steadyshot (IC401 on the SY-323 
board).
E
6
2
1
0
Lens initializing failure.
Check or replacement of the IC for steadyshot (IC401 on the SY-323 
board).
E
6
2
1
1
Lens overheating (PITCH).
Check the HALL element (PITCH) of optical image stabilizer (pin 8, 0 
of CN403 on the SY-323 board). If it is OK, check PITCH angular velocity 
sensor (SE401 on the SY-323 board) peripheral circuits.
E
6
2
1
2
Lens overheating (YAW).
Check the HALL element (YAW) of optical image stabilizer (pin qa, qd 
of CN403 on the SY-323 board). If it is OK, check YAW angular velocity 
sensor (SE401 on the SY-323 board) peripheral circuits.
E
6
2
2
0
Abnormality of thermistor.
Check the OIS temp sensor of optical image stabilizer (pin ea of CN403 
on the SY-323 board).
E
9
1
0
1
Abnormality when flash is being charged. Checking of flash unit or replacement of flash unit. (Note 1)
E
9
4
0
0
Internal memory fault.
Inspect the internal memory (IC211 on the SY-323 board).
E
9
5
0
0
GPS hardware error.
Check whether the FP-1536 flexible board of connected between SY-323 
board and RL-127 board is broken, and check whether it is inserted im-
perfectly. If there is no problem the coaxial cable or flexible board, inspect 
or replacement of the SY-323 or RL-127 board.
E
9
5
0
1
Acceleration sensor hardware error. 
(GPS hardware error)
Check whether the FP-1536 flexible board of connected between SY-323 
board and RL-127 board is broken, and check whether it is inserted im-
perfectly. If there is no problem the coaxial cable or flexible board, inspect 
or replacement of the SY-323 or RL-127 board.
E
9
5
0
2
Electronic compass hardware error.
(GPS hardware error)
Check whether the FP-1536 flexible board of connected between SY-323 
board and RL-127 board is broken, and check whether it is inserted im-
perfectly. If there is no problem the coaxial cable or flexible board, inspect 
or replacement of the SY-323 or RL-127 board.
Note 1: After repair, be sure to perform “1-7. PROCESS AFTER FIXING FLASH ERROR”.
Note 2: Functions of codes with * mark are not provided in this unit.
*
*
Page of 28
Display

Click on the first or last page to see other DSC-HX10 / DSC-HX10V (serv.man2) service manuals if exist.