DSC-H300_ADJ
Sony Corporation
Revision History
SECTION 5
ADJUSTMENT
ADJ
983475551.pdf
2013J08-1
© 2013.10
Published by Sony Techno Create Corporation
Ver. 1.0 2013.10
9-834-755-51
DSC-H300
Link
• PREPARATIONS
• Adjustment Items When Replacing Lens
Block Assy, CCD Block Assy, Main Board
Assy, ST Board Assy
• List of Service Tools and Equipment
• Keys and Functions
• Connecting the Equipment
• Setting the Adjustment Mode
• Enabling the Adjustment
• MB/LCD FUNCTION CHECK
• CAMERA SECTION ADJUSTMENTS
• Writing Lens data
• Setting Default Gyro Value
• Focus Adjustment
• OB Adjustment
• WB/AGC Adjustment
• MeShut26 Adjustment
• MeShut80 Adjustment
• Dark DP Adjustment
• Light/S.S Adjustment
• Flash WB Adjustment
• Lens Option
• Set Language Destination
Ver.
Date
History
Contents
S.M. Rev.
issued
1.0
2013.10
Official Release
—
—
DSC-H300_ADJ
5-2
5. ADJUSTMENT
5-1. PREPARATIONS
5-1-1. Adjustment Items When Replacing Lens Block Assy, CCD Block Assy, Main Board Assy, ST Board Assy
When replacing these parts, adjust the items indicated by “ z ” in the following table.
Adjustment item
Replaced parts
Lens Block Assy
CCD Block Assy
Main Board Assy
ST Board Assy
Writing Lens data code
z
z
Setting Default Gyro Value
z
z
Focus Adjustment
z
z
z
OB Adjustment
z
z
z
WB/AGC Adjustment
z
z
z
MeShut26 Adjustment
z
z
z
MeShut80 Adjustment
z
z
z
Dark DP Adjustment
z
z
z
Light/S.S Adjustment
z
z
z
Flash WB Adjustment
z
z
z
z
Lens Option
z
Set Language Destination
z
5-1-2. List of Service Tools and Equipment
Personal computer
(Note)
(Note)
J-1
J-3
J-5
J-4
Clear chart
J-6082-560-A
J-6082-560-A
J-6
9 colors chart
J-6082-562-A
J-6082-562-A
J-7
Flange back
adjustment jig
J-6082-563-A
adjustment jig
J-6082-563-A
or
Infinity jig (1000mm)
J-6082-747-A
J-6082-747-A
J-2
Small pattern box
PTB-1450
J-6082-557-A
PTB-1450
J-6082-557-A
J-9
Camera table
J-6082-384-A
J-6082-384-A
J-8
Dedicated USB cable
1-834-311-51
1-834-311-51
J-10
Background paper
J-2501-130-A
J-2501-130-A
SD-Card
HR 15/51:HR 6 (size AA)
Nickel-Metal Hydride
batteries (× 4)
Nickel-Metal Hydride
batteries (× 4)
Fig. 5-1-1
Note:
Personal computer
OS
Personal computer
OS
: Windows2000/XP Home/XP Pro/Vista/7
RAM : 256 MB (1 GB: Vista/7) or more recommended
USB : 2.0 recommended (also compatible with 1.1)
USB : 2.0 recommended (also compatible with 1.1)
5-1-3. Keys and Functions
Following are keys and functions used in adjustment. (Fig. 5-1-2)
Select items: v/V/b/B
Set: z
Set: z
ON/OFF (Power)
Control button
W/T (Zoom)
W : zoom out
T : zoom in
W : zoom out
T : zoom in
Shutter
button
button
(Playback) button
Fig.
5-1-2
5-1-4. Connecting the Equipment
Insert the SD-Card and the batteries as shown below. (Fig. 5-1-3)
Ensure the notched corner
faces correctly.
faces correctly.
Fig.
5-1-3
Note:
Use the fully charged batteries in adjustment.
Use the fully charged batteries in adjustment.
Set the camera on the Camera table. (Fig. 5-1-4)
Camera table
(J-6082-384-A)
(J-6082-384-A)
Fig.
5-1-4
DSC-H300_ADJ
5-3
5-2. MB/LCD FUNCTION CHECK
The MB (Main Board)/LCD Function Check order is as follows.
If NG appears for more than one check item, confirm the adjusting
environment and recheck. (Fig. 5-2-4)
environment and recheck. (Fig. 5-2-4)
Ver : 01.0000
RTC :
Iris :
MSHUT :
ZOOM :
STROB :
CARD :
Mem :
AUDIO:
Diff -
RTC :
Iris :
MSHUT :
ZOOM :
STROB :
CARD :
Mem :
AUDIO:
Diff -
Cal Err
NG
-OK
-OK
-OK
-OK
-OK
-OK
-OK
-NG
-OK
-OK
-OK
RE
-OK
48
Fig. 5-2-4
Example: NG appears for
STROB.
1) Check that the camera is on the adjustment mode.
Note:
For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
2) Place the camera in front of the Small pattern box (PTB-1450). (Fig. 5-2-2)
3) Press the flash unit pop-up button to raise the flash.
4) Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item. Choose “MB/LCD”,
press the Control button “ z ”, select “OK”, and press the Control button “ z ” to start.
Note:
If the check is disabled, refer to “5-1-6. Enabling the Adjustment” to enable the check. (Page 5-3)
5) Confirm the indication on the screen.
If OK appears for all check items, press the “
(Playback)” button
to return to adjustment menu. (Fig. 5-2-3)
Ver : 01.0000
RTC :
Iris :
MSHUT :
ZOOM :
STROB :
CARD :
Mem :
AUDIO:
Diff -
RTC :
Iris :
MSHUT :
ZOOM :
STROB :
CARD :
Mem :
AUDIO:
Diff -
FINISH
OK
-OK
-OK
-OK
-OK
-OK
-OK
-OK
-OK
-OK
-OK
-OK
-OK
-OK
RE
-OK
49
Fig. 5-2-3
Function check items
Item
Description
RTC
Compare Crystal RTC time and OS time. If Crystal RTC time and OS time are the same, conform to spec.
Iris
Change difference aperture to check their luminance value. If it has different luminance value, conform to spec.
MSHUT
Change difference Mechanical Shutter ON/OFF to check their luminance value. If it has different luminance value,
conform to spec.
conform to spec.
ZOOM
Change difference Lens ZOOM IN/OUT position to check their zoom position value. If it has different zoom position
value, conform to spec.
value, conform to spec.
STROB
Strobe board flash function, check if it can be triggered or not.
CARD
Check Memory card socket can be read/written.
Mem
Check Internal memory size, conform to spec.
AUDIO
REC/PLAY audio file, check Microphone and Speaker are working.
Handling of 9 Colors Chart
When performing adjustments using the 9 colors chart, insert the
transparent window in the lower right position. (Fig. 5-2-1)
transparent window in the lower right position. (Fig. 5-2-1)
Small pattern box
9 colors chart
Transparent window
Fig. 5-2-1
5-1-5. Setting the Adjustment Mode
1) Download the adjustment tool “ADJ_Tool_H300_Ver[][][].zip” from the TISS homepage.
Uncompress the “ADJ_Tool_H300_Ver[][][].zip”, then confirm that it includes the following items.
• EnableTest.txt
• USB Driver (Folder): Refer to “5-3-12. Set Language Destination”. (Page 5-10)
• Service Tool (Folder): Refer to “5-3-12. Set Language Destination”. (Page 5-10)
• Sub_ADJ_Tool (Folder): Refer to “5-3-1. Writing Lens data” and “5-3-2. Setting Default Gyro Value”. (Page 5-4)
• USB Driver (Folder): Refer to “5-3-12. Set Language Destination”. (Page 5-10)
• Service Tool (Folder): Refer to “5-3-12. Set Language Destination”. (Page 5-10)
• Sub_ADJ_Tool (Folder): Refer to “5-3-1. Writing Lens data” and “5-3-2. Setting Default Gyro Value”. (Page 5-4)
2)
Save the uncompressed file “EnableTest.txt” in the root directory of the SD-Card after formatting the it.
Note:
Saving it in other directories causes a malfunction of program.
Save the SD-Card after confirming that the “EnableTest.txt” is empty.
Be sure to format the SD-Card on the camera.
If “EnableTest.txt” is still remained after the adjustment, delete it.
Save the SD-Card after confirming that the “EnableTest.txt” is empty.
Be sure to format the SD-Card on the camera.
If “EnableTest.txt” is still remained after the adjustment, delete it.
3) With the camera turned off, insert the SD-Card with the “EnableTest.txt” into the Memory card slot of the camera.
4) Press the “
(Playback)” button while turn the “T (W/T)” lever and the Control button “ z ”.
5) After a few seconds, the Adjustment mode screen will appear on the LCD display. (Fig. 5-1-5)
6) Press the “
(Playback)” button, the initial screen for the adjustment mode will appear. (Fig. 5-1-6)
Ver : 1.0000
No Box No.
DscID:80814810
MB/LCD
AF Clbt
OB Clbt
Wb/Agc
MeShut26
MeShut80
Light/S.S
Dark DPC
FlashWB
AF Clbt
OB Clbt
Wb/Agc
MeShut26
MeShut80
Light/S.S
Dark DPC
FlashWB
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
USB Mode
Boot Type
Auto Clbt
AF Lamp
Boot Type
Auto Clbt
AF Lamp
OIS Check
OK
Func Check :
LensOption
CKS 73983317
CKS 73983317
CT26300
Index : 08
1.0000
A0D8P7000029
Index : 08
HW : 0
CLBTINFO
V
V
V
FOCUS
OBCLBT
WB/AGC
(Infinity)
(BLACK)
(LV10)
Fig. 5-1-5
Fig. 5-1-6
5-1-6. Enabling the Adjustment
The item that has been adjusted may be disabled to be readjusted.
If the readjustment is required, or when replacing Lens Block Assy, CCD Block Assy and ST Board Assy, it is necessary to enable
the adjustment upon the following procedure
If the readjustment is required, or when replacing Lens Block Assy, CCD Block Assy and ST Board Assy, it is necessary to enable
the adjustment upon the following procedure
.
1) Press the Control button “ b ” “ B ” and “ v ” “ V ” to choose an adjustment item.
2) Press the “
(Playback)” button.
3) Press the Control button “ b ”.
(Disable
(Disable
“00001”
→ Disable “00000”) (Fig. 5-1-7)
Example: For MB/LCD
A0BB7K000005
Index : 12
HW : 0
V
V
(BLACK)
A0BB7K000005
Index : 12
HW : 0
V
V
V
(BLACK)
1.0000
CLBTINFO
V
FOCUS
OBCLBT
WB/AGC
(Infinity)
(LY10)
Disable
00000
RunLCD
00000
Video
00000
OnlyLCD
00000
1.0000
CLBTINFO
FOCUS
OBCLBT
WB/AGC
(Infinity)
(LY10)
Disable
00001
RunLCD
00000
Video
00000
OnlyLCD
00000
Disabled
Enabled
Fig. 5-1-7
Equipment required: Small pattern box (PTB-1450)
Cover camera lens and
Small pattern box (PTB-1450)
Small pattern box (PTB-1450)
(All black)
9 colors chart
Small pattern box
(PTB-1450)
(PTB-1450)
5 mm or less (Tele end)
Black cloth
Camera
Fig. 5-2-2
DSC-H300_ADJ
5-4
5-3. CAMERA SECTION ADJUSTMENTS
5-3-1. Writing Lens data
Introduction:
- Please handle lens with care.
- Perform the operation additionally when replacing Main board or Lens.
- Read and record the lens data on the QR Code Label or Lens data Label attached to the lens. (Fig. 5-3-1)
- Record of numbers. (7 digit)
- Please handle lens with care.
- Perform the operation additionally when replacing Main board or Lens.
- Read and record the lens data on the QR Code Label or Lens data Label attached to the lens. (Fig. 5-3-1)
- Record of numbers. (7 digit)
010 1118
Lens data
0 1 0 111 8
(Fig.
5-3-1)
Preparations:
Put the folder “Wrirte_Lens Data” downloaded in “5-1-5. Setting the Adjustment Mode” (Page 5-3) on any place of the PC.
Confirm that includes the following items.
• Write_LensCode_v[][][].exe
• UI43Api.dll
• Write_LensCode_v[][][].exe
• UI43Api.dll
The USB Driver is sane as “5-3-12. Set Language Destination”.
Procedure:
1) Check that the camera is on the adjustment mode.
1) Check that the camera is on the adjustment mode.
Connect the camera and the PC.
2) Double click the “Write_LensCode_v[][][].exe” to start up the writing tool. (Fig. 5-3-2)
(Fig.
5-3-2)
3) Enter the recorded lens data in the “Data code” text field.
4) Click the “Write” button.
5) The message “Write Code To Camera OK !!” will be displayed.
4) Click the “Write” button.
5) The message “Write Code To Camera OK !!” will be displayed.
(Fig.
5-3-3)
5-3-2. Setting Default Gyro Value
Perform the this operation additionally when replacing Main board or Lens.
Preparations:
Put the folder “Set_Default Gyro Value” downloaded in “5-1-5. Setting the Adjustment Mode” (Page 5-3) on any place of the PC.
Confirm that includes the following items.
• Set_DefaultGyro_v[][][].exe
• UI43Api.dll
• Set_DefaultGyro_v[][][].exe
• UI43Api.dll
The USB Driver is sane as “5-3-12. Set Language Destination”.
Procedure:
1) Check that the camera is on the adjustment mode.
1) Check that the camera is on the adjustment mode.
Connect the camera and the PC.
2) Double click the “Set_DefaultGyro_v[][][].exe” to start up the writing tool. (Fig. 5-3-4)
3) Click the “Set Default ” button.
3) Click the “Set Default ” button.
(Fig.
5-3-4)
4) In case of the setting is finished normally, the setting completion indication appears on the screen. (Fig. 5-3-5)
The power of the camera turns off automatically.
(Fig.
5-3-5)