DSC-H3 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 29

Read Sony DSC-H3 (serv.man4) Service Manual online

6-28
DSC-H3_ADJ
The buttons on this screen provide the following functions.
[Read] button: Reads and displays the previous data (Dp, Dy)
from the SY-185 board.
[Save] button: Saves the previous data (Dp, Dy) in the PC as a
file.
[Load] button: Loads and displays the previous data (Dp, Dy)
from the file saved in the PC.
• Default file name is as follows:
2) Input the previous data (Dp, Dy) into screen.
If the previous data cannot be read, give a check to the checkbox
at lower left of screen.
3) Input the sensitivity of respective sensors (S
501
, S
502
) read at
“Preparation” into the screen.
If the angular velocity sensor was not replaced, give a check
to the checkbox at the lower left of the screen.
4) Input the PITCH/YAW data of lens (L
1
, L
2
) read at “Prepara-
tion” into the screen.
If the lens was not replaced, give a check to the checkbox at
the lower left of the screen.
5) Click the [OK] button, and the adjustment data is then calcu-
lated from the sensor sensitivity value and the calculation re-
sult is written to the memory in the camera.
6) Upon successful completion of the data writing, the following
screen will appear. Check that the steady shot function oper-
ates normally.
9-4. Angular Velocity Sensor Sensitivity Adjustment
[Adjusting method]
1) Click the [Start] button of Camera Adjustment 8, and Type S
or Type M will be automatically checked, and then the follow-
ing screen will appear.
Type S
Type M
DSC-H3_DpDyDT_xxxxxxxx_yyyymmdd.dat
Date
USB serial number
Data name
Ver. 1.1  2007.10
Page of 41
Display