Read Sony DSC-H2 (serv.man12) Service Manual online
SERVICE MANUAL
Auto-ADJ
• Change of Automatic Adjustment Program
Version of Automatic Adjustment Program has
been changed from Ver_1.0r01 into Ver_1.1r02.
been changed from Ver_1.0r01 into Ver_1.1r02.
: Points changed portion.
!
: Points deleted portion.
6-1. CAMERA SECTION ADJUSTMENTS
1-2.
ADJUSTMENT PROGRAMS
1-2-1.
Automatic Adjustment Program
2.
Start of Automatic Adjustment Program
(Service manual page 6-10)
Double-click the application file (DSC-H2 Auto-Adj
Ver_1.1r02.exe), and the Automatic Adjustment Program will start.
Ver_1.1r02.exe), and the Automatic Adjustment Program will start.
Note:
[]
(numeric value) of the file name varies depending on the
version of Automatic Adjustment Program.
Ver. 1.1 2007.05
Sony EMCS Co.
9-876-937-89
2007E0500-1
© 2007.5
Published by Kohda TEC
SUPPLEMENT-1
File this supplement with the service manual.
(DI07-013)
DSC-H2
DSC-H2_ADJ
• Change of Automatic Adjustment Program
• Change of Adjustment Address
• Change of Adjustment Address
(Color Reproduction Adj. & Check)
• Addition of “How to read the sensitivity data of
angular velocity sensor”
3.
Function of Each Button on Main Menu Screen
(Service manual page 6-10)
When the Automatic Adjustment Program started, the Main Menu
screen in Fig. 6-1-10 will appear. On this screen, select each ad-
justment section.
screen in Fig. 6-1-10 will appear. On this screen, select each ad-
justment section.
Fig. 6-1-10
6
This part indicates the version of Automatic Adjustment Pro-
gram.
gram.
5
3
2
1
4
6
#
— 2 —
DSC-H2_ADJ
• Change of Adjustment Address
(Color Reproduction Adj. & Check)
: Points changed portion.
1-4.
CAMERA SYSTEM ADJUSTMENTS
1-4-2.
Adjustment Items of Camera System Adjust-
ment
ment
(Service manual page 6-15)
_
_
_
_
_
_
Button Name
Adjustment
Subject
Adjustment
Page
Adjustment
Address
Color Reproduction
Adj. & Check
Adj. & Check
9 color chart
(Standard picture frame)
(Standard picture frame)
6E
50 to 57
CCD Linearity Check
CCD White Defect
Compensation Check
Compensation Check
CCD Black Defect
Compensation Check
Compensation Check
Clear chart
(Standard picture frame)
(Standard picture frame)
CAMERA Adjustment 4
Table 6-1-3
• Addition of “How to read the sensitivity data
of angular velocity sensor”
&
: Points added portion.
: Points changed portion.
: Points changed portion.
1-4-3.
Adjustment Method
11.
CAMERA Adjustment 7
(Service manual page 6-24)
Preparation:
1) Read the PITCH sensor (SY-150 board SE501) sensitivity writ-
1) Read the PITCH sensor (SY-150 board SE501) sensitivity writ-
ten on repair parts, and named this as S
501
.
2) Read the YAW sensor (SY-150 board SE502) sensitivity writ-
ten on repair parts, and named this as S
502
.
Fig. 6-1-49
1
2
3
4
1
2
3
4
SY-150 BOARD (SIDE A)
YAW sensor sensitivity
t
S
502
PITCH sensor sensitivity
t
S
501
SE501
SE502
PP
YY
How to read the sensitivity data of angular velocity sen-
sor
sor
With the pins 1 and 2 of angular velocity sensor placed in the
lower position, read the data value.
lower position, read the data value.
6 0
Hand Writing
1
2
4
3
For the sensor sensitivity value 60
Description example :
+
Display