1. SERVICE NOTE
• NOTE FOR REPAIR
[Discharging of the FLASH unit’s charging capacitor]
The charging capacitor of the FLASH unit is charged up to the
maximum 300 V potential.
There is a danger of electric shock by this high voltage when the
capacitor is handled by hand.  The electric shock is caused by the
charged voltage which is kept without discharging when the main
power of the DSC-H1 is simply turned off.  Therefore, the remaining
voltage must be discharged as described below.
Preparing the Short Jig
To preparing the short jig. a small clip is attached to each end of a
resistor of 1 k
 /1 W (1-215-869-11)
Wrap insulating tape fully around the leads of the resistor to prevent
electrical shock.
1 k
/1 W
Wrap insulating tape.
Make sure that the flat cable and flexible board are not cracked of 
bent at the terminal.
Do not insert the cable insufficiently nor crookedly.
Cut and remove the part of gilt 
which comes off at the point.
(Take care that there are 
some pieces of gilt left inside)
When remove a connector, don't pull at wire of connector.
Be in danger of the snapping of a wire.
When installing a connector, don't press down at wire of connector.
Be in danger of the snapping of a wire.
Discharging the Capacitor
1
 Remove the main section.
2
 Discharge the capacitor on the ST-123 board for about 10 seconds
     by using the short jig.
1
 Discharging the capacitor
Capacitor
ST-123 board
Short jig (
1k
/1W
)