DSC-G1 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 9

Read Sony DSC-G1 (serv.man4) Service Manual online

6-7
DSC-G1_ADJ
3.
Function of Each Button on Main Menu Screen
When the Automatic Adjustment Program started, the Main Menu
screen in Fig. 6-1-9 will appear. On this screen, select each adjust-
ment section.
Fig. 6-1-9
1
[Connecting the Equipment] button
A connection diagram of the equipment is displayed.
2
[CONNECT] button
The mode of Camera is switched to the Adjustment Mode.
When the Adjustment Mode has switched normally, the op-
eration of the buttons 4 - 0 is enabled.
3
[END] button
The mode of Camera is switched to the normal mode.
When the normal mode has switched correctly, the Automatic
Adjustment Program is finished.
4
[DESTINATION DATA WRITE] button
The “DESTINATION DATA WRITE” screen appears.
5
[USB SERIAL N0. INPUT] button
The “USB SERIAL No. INPUT” screen appears.
6
[VIDEO SYSTEM ADJUSTMENT] button
The “VIDEO SYSTEM ADJUSTMENT” screen appears.
7
[CAMERA SYSTEM ADJUSTMENT] button
The “CAMERA SYSTEM ADJUSTMENT” screen appears.
8
[LCD SYSTEM ADJUSTMENT] button
The “LCD SYSTEM ADJUSTMENT” screen appears.
9
[SERVICE MODE] button
The “SERVICE MODE” screen appears.
0
[DATA BACKUP] button
The “DATA BACKUP” screen appears.
qa
This part indicates the version of Automatic Adjustment Pro-
gram.
1-2.
ADJUSTMENT  PROGRAM
The DSC-G1 is adjusted by the Automatic Adjustment Program.
The Automatic Adjustment Program enters automatically via the
SeusEX the adjustment operations that were formerly entered
manually by the adjustment remote commander (some items may
be adjusted by manual operation on the operation screen of the
SeusEX).
1.
Precautions When Using Automatic Adjustment
Program
1) The Automatic Adjustment Program writes the adjustment re-
sults such as EVR data to the set through two-way communi-
cation with the camera via the SeusEX. Accordingly, the Au-
tomatic Adjustment Program must be used in the environment
where the SeusEX operates.
2) The Automatic Adjustment Program cannot be used when the
SEUS or the SeusCam is running. Exit the SEUS or the
SeusCam before using the Automatic Adjustment Program.
3) The SeusEX must be already started on the PC when using the
Automatic Adjustment Program. With the SeusEX not started,
some adjustment items will take time in adjustment.
4) The program run time may vary depending on the environ-
ment of the personal computer used.
2.
Start of Automatic Adjustment Program
Double-click the application file (DSC-G1 Auto-Adj
Ver_1.0r01.exe), and the Automatic Adjustment Program will start.
3
5
4
7
6
2
1
9
q;
qa
8
Page of 36
Display

Click on the first or last page to see other DSC-G1 (serv.man4) service manuals if exist.