DSC-G1 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 34

Read Sony DSC-G1 (serv.man4) Service Manual online

6-32
DSC-G1_ADJ
(3) AGING_MREC
In the AGING_MREC mode, motion pictures are continuously
recorded for the time (sec.) set to the “Rec Time” at the interval
(sec.) set to the “Rec Interval”.
At the start of AGING_MREC, the counter in the camera is ini-
tialized. This counter counts the number of recording times dur-
ing the execution of AGING_MREC, and it holds the counts even
during the power off.
AGING_MREC screen and functions of each item
1
[Preparation] button
Notes for aging is displayed.
2
Rec Time setting and display
The setting of recording time (sec.) is displayed. The setting
can be changed by entering a numeric value in this field.
3
Rec Interval setting and display
The setting of recording interval (sec.) is displayed. The set-
ting can be changed by entering a numeric value in this
field.
4
[START] button
The AGING_MREC starts. In the AGING_MREC mode, the
aging starts immediately when the [START] button is clicked.
At the battery end, the AGING_MREC stops. To interrupt the
AGING_MREC, use the [STOP]  button, though the
AGING_MREC stops also by the power off or RESET button.
5
[STOP] button
The AGING_MREC stops.
6
[GET] button
After the AGING_MREC was executed, the number of record-
ing times is got from the counter in the camera. The result is
displayed in the “Count” display field.
7
Count display
The number of recording times got by the [GET] button is dis-
played.
(4) AGING_PB
In the AGING_PB mode, pictures are continuously played back at
the interval (sec.) set to the “Play Back Interval”.
At the start of AGING_PB, the counter in the camera is initial-
ized. This counter counts the number of play back times during
the execution of AGING_PB, and it holds the counts even during
the power off.
AGING_PB screen and functions of each item
1
[Preparation] button
Notes for aging is displayed.
2
Play Back Interval setting and display
The setting of play back interval (sec.) is displayed. The set-
ting can be changed by entering a numeric value in this field.
3
[START] button
The AGING_PB starts. In the AGING_PB mode, the aging
starts immediately when the [START] button is clicked.
At the battery end, the AGING_PB stops. To interrupt the
AGING_PB, use the [STOP] button, though the AGING_PB
stops also by the power off or RESET button.
4
[STOP] button
The AGING_PB stops.
5
[GET] button
After the AGING_PB was executed, the number of play back
times is got from the counter in the camera. The result is dis-
played in the “Count” display field.
6
Count display
The number of play back times got by the [GET] button is
displayed.
6
4
5
1
7
2 3
5
3
4
1
6
2
Page of 36