DSC-F828
10. CAMERA Adjustment 6
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. AF Laser Axis Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[CAMERA Adjustment 6 Start]
 button.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
(For the Flash adjustment box, refer to “4. Preparing the Flash
Adjustment Box” (see page 6-6).)
Fig. 6-1-52
4) Click the 
[OK]
 button, and the “2. AF Laser Axis Check” will
be executed. The following message is displayed. Attach the
AF Laser axis frame on the monitor TV screen in accordance
with the message.
Fig. 6-1-53
5) If the 
[OK]
  button is clicked, the following message is dis-
played. Set the ZOOM to the WIDE end and click the 
[OK]
button.
Fig. 6-1-54
6) After that, the next message is displayed. Check that all holo-
gram patterns are within the inspection frame.
Fig. 6-1-55
Fig. 6-1-56
7) If the 
[OK]
  button is clicked, the following message is dis-
played. Set the ZOOM to the TELE end and click the 
[OK]
button.
Fig. 6-1-57
8) After that, the next message is displayed. Check that all holo-
gram patterns are not unfocused.
Fig. 6-1-58
9) Upon completion of “2. AF Laser Axis Check”, “3. Release of
Data Setting during Camera Adj.” is executed.
10) Upon successful completion of all items of the CAMERA
Adjustment 6, the following message is displayed. Click the
[OK]
 button.
Fig. 6-1-59
Inspection frame