6-14
DSC-F828
1-4-3.
Adjusting Method
1.
CAMERA Adjustment 1
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. IRIS Reset Sensor Adj.
3. Reset the Camera
4. Flange Back Adj.
5. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[CAMERA Adjustment 1 Start]
 button.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
Fig. 6-1-16
4) If the 
[OK]
 button is clicked, “2. IRIS Reset Sensor Adj.” will
be executed.
5) Upon successful completion “2. IRIS Reset Sensor Adj.”, “3.
Reset the Camera” is executed.
6) Upon successful completion of the “3. Reset the Camera”, the
following message is displayed during execution in “4. Flange
Back Adj.”. Set the ZOOM to the TELE end and click the 
[OK]
button.
Fig. 6-1-17
7) Upon completion of “4. Flange Back Adj.”, “5. Release of Data
Setting during Camera Adj.” is executed.
8) Upon successful completion of all items of the CAMERA Ad-
justment 1, the following message is displayed. Click the 
[OK]
button.
Fig. 6-1-18