5-25
17. CCD Black Defect Compensation
Mode
STILL
Subject
Clear chart
(25 cm from the front of lens)
Measurement Point
Displayed data of page: 6, address: 55
Measuring Instrument Adjusting remote commander
Adjustment Page
7
Adjustment Address
60 to 87
Note 1:
Check that there are no dust, no dirt and reflection of the
clear chart.
Note 2:
Any subject other than the clear chart should be in the
screen.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
4)
Select page: F, address: DF, after noting down the data, set
data: 4C, and press the PAUSE button.
5)
Select page: 6, address: 2C, and set data: 01.
6)
Select page: 6, address: 90, and set data: 00.
7)
Select page: 6, address: 91, and set data: 03.
8)
Select page: 6, address: 92, and set data: 00.
9)
Select page: 6, address: 93, and set data: 00.
10) Select page: 6, address: 6C, and set data: 01.
11) Select page: 6, address: 01, set data: 79, and press the PAUSE
button.
12) Select page: 6, address: 30, and set data: 01.
13) Wait for 4 seconds.
14) Select page: 6, address: 01, set data: 8D, and press the PAUSE
button. (The CCD black defect compensation is performed
and the compensation data is stored in page: 7, addresses: 60
to 87)
15) Select page: 6, address: 02, and check that the data is “01”.
16) Select page: 6, address: 55, and check the data.
00 to 0A: Normal
0B to FF: Defective
17) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
18) Select page: F, address: DF, set data: 5A, and press the PAUSE
button.
19) Select page: 6, address: 01, set data: 89, and press the PAUSE
button.
20) Select page: 6, address: 02, and check that the data is “01”.
21) Select page: 6, address: 55, and check the data .
00: Normal
01 to FF: Defective
Processing after Completing Adjustments:
1)
Select page: F, address: DF, set data noted down at step 4)
and press the PAUSE button of the adjusting remote
commander.
2)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
3)
Select page: 6, address: 2C, and set data: 00.
4)
Select page: 6, address: 30, and set data: 00.
5)
Select page: 6, address: 6C, and set data: 00.
6)
Select page: 6, address: 91, and set data: 00.
7)
Select page: 5, address: F1, and set data: 00.
8)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
9)
Select page: 0, address: 01, and set data: 00.
18. CCD White Defect Compensation
Mode
STILL
Subject
Clear chart
(25 cm from the front of lens)
Measurement Point
Displayed data of page: 6, address: 55
Measuring Instrument Adjusting remote commander
Adjustment Page
7
Adjustment Address
88 to A3
Note 1:
Check that there are no dust, no dirt and reflection of the
clear chart.
Note 2:
Any subject other than the clear chart should be in the
screen.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
4)
Select page: F, address: DE, after noting down the data, set
data: 1E, and press the PAUSE button.
5)
Select page: F, address: E3, after noting down the data, set
data: 08, and press the PAUSE button.
6)
Select page: 6, address: 01, set data: 8B, and press the PAUSE
button. (The CCD white defect compensation is performed
and the compensation data is stored in page: 7, addresses: 88
to A3)
7)
Select page: 6, address: 02, and check that the data is “01”.
8)
Select page: 6, address: 55, and check the data.
00 to 7F: Normal
80 to FF: Defective
9)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
10) Select page: F, address: DE,  set data: 0F, and press the PAUSE
button.
11) Select page: F, address: E3, set data: A0, and press the PAUSE
button.
12) Select page: 6, address: 01, set data: 87, and press the PAUSE
button.
13) Select page: 6, address: 02, and check that the data is “01”.
14) Select page: 6, address: 55, and check the data.
00: Normal
01 to FF: Defective
Processing after Completing Adjustments:
1)
Select page: F, address: DE, set data noted down at step 4)
and press the PAUSE button of the adjusting remote com-
mander.
2)
Select page: F, address: E3, set data noted down at step 5)
and press the PAUSE button.
3)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
4)
Select page: 5, address: F1, and set data: 00.
5)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
6)
Select page: 0, address: 01, and set data: 00.
Page of 109