XVM-H65 - Sony Car Audio Service Manual (repair manual). Page 13

Read Sony XVM-H65 Service Manual online

13
XVM-H65
5-12-6. R Sub Contrast Adjustment
Adjustment Method:
1) Select R SUB CONT from the FOR FACTORY MODE.
2) Connect oscilloscope between TP812 (+) and TP500 (–).
3) Adjust so that the signal level F stands at the specified value
using the  
R
  and  
r
  keys on the remote controller.
Specified value: 3.2 ± 0.1 V
Adjustment location: Display board
5-12-7. B Sub Contrast Adjustment
Adjustment Method:
1) Select B SUB CONT from the FOR FACTORY MODE.
2) Connect oscilloscope between TP810 (+) and TP500 (–).
3) Adjust so that the signal level G stands at the specified value
using the  
R
  and  
r
  keys on the remote controller.
Specified value: 3.2 ± 0.1 V
Adjustment location: Display board
5-12-8. 
γ
 1 Adjustment
Adjustment Method:
1) Select Gamma1 from the FOR FACTORY MODE.
2) Connect oscilloscope between TP811 (+) and TP500 (–).
3) Adjust so that the signal level H stands at the specified value
using the  
R
  and  
r
  keys on the remote controller.
Specified value: 1.9 ± 0.1 V
Adjustment location: Display board
5-12-9. 
γ
 2 Adjustment
Adjustment Method:
1) Select Gamma2 from the FOR FACTORY MODE.
2) Connect oscilloscope between TP811 (+) and TP500 (–).
3) Adjust so that the signal level I stands at the specified value us-
ing the  
R
  and  
r
  keys on the remote controller.
Specified value: 3.1 ± 0.1 V
Adjustment location: Display board
5-12-10. VCO Free Run Adjustment
Adjustment Method:
1) Select VCO Free from the FOR FACTOR MODE.
2) Connect frequency counter between TP407 (+) and TP404 (–).
3) Adjust so that the reading on the counter stands at the specified
value using the  
R
  and  
r
  keys on the remote controller.
Specified value: 15,734 ± 50 Hz
Adjustment location: Display board
5-12-11. V POS Adjustment
Adjustment Method:
1) Input mono scope signal from the NTS pattern generator.
2) Select PLL/V POS from the FOR FACTORY MODE.
3) Observe the mono scope screen on the monitor and adjust so that
the screen is vertically symmetrical using the  
R
  and  
r
  keys on
the remote controller.
5-12-12. H POS Adjustment
Adjustment Method:
1) Input mono scope signal from the NTS pattern generator.
2) Select H POS from the FOR FACTORY MODE.
3) Observe the mono scope screen on the monitor and adjust so that
the screen is horizontally symmetrical using the  
R
  and  
r
  keys
on the remote controller.
F
0V
G
0V
H
0V
I
0V
Page of 35
Display

Click on the first or last page to see other XVM-H65 service manuals if exist.