XVM-6100, XVM-61EX (serv.man2) - Sony Car Audio Service Manual (repair manual). Page 4

Read Sony XVM-6100 / XVM-61EX (serv.man2) Service Manual online

– 4 –
SECTION 2
ELECTRICAL ADJUSTMENTS
Equipment
Use the following test equipment for alignment.
• Oscilloscope dual trace, 10 MHz band or above with delay mode
(use a 10 to 1 probe unless otherwise instructed.)
• NTSC color bar generator
• PAL color bar generator
• DC power supply
• Digital voltmeter
• XT-61VE (TV tuner unit of XTL-610E) (XVM-61EX only)
• Frequency counter
Equipment Connections
Make the test equipment connections as shown below (unless
instructed otherwise) and perform the alignment.
XVM-61EX :
NAVI INPUT
(VIDEO)
color bar
generator
XT-61VE
XVM-611EX
VIDEO output
(75 
)
MONITOR OUTPUT
INPUT 1
(VIDEO)
MONITOR OUTPUT
CONTROLLER
XA-601
XVM-611
color bar
generator
VIDEO output
(75 
)
RM-X6100
XVM-6100 :
 MONITOR SECTION
Voltage Adjustment
Setting :
DIMMER selector (S701) : HIGH
BRIGHT dial (RV702)
: Max. (light)
VOL dial (RV301)
: Max.
Procedure :
1. Input the color bar (chroma off) signal from NTSC color bar
generator and display on the monitor screen.
2. Connect the digital voltmeter to CL66 on the monitor main
board.
3. Adjust RV401 (+5V) so that the digital voltmeter reads 5
±
0.1 V
DC.
4. Connect the digital voltmeter to CL86 on the monitor main
board.
5. Adjust RV601 (+9V) so that the digital voltmeter reads 8.5
±
0.1 V
DC.
Connection points : Monitor main board Refer to page 5.
Alignment points : Monitor main board Refer to page 5.
RGB Adjustment
Procedure :
1. Input the color bar (chroma off) signal from NTSC color bar
generator and display on the monitor screen.
2. Connect the digital voltmeter to CL151 on the monitor main
board.
3. Adjust RV213 (OFFSET) so that the digital voltmeter reads
2.3
±
0.1 V DC.
4. Connect the oscilloscope to CL42 on the monitor main board.
5. Adjust RV212 (COM CUT) so that the lower black level is
6.2
±
0.05 V DC.
6. Adjust RV208 (COM DRIVE) so that the upper 100% white
level is 9.2
±
0.05 V DC.
7. Repeat steps 5 & 6 until the items in the standards are satisfied.
8. Connect the oscilloscope to CL41 of the monitor main board.
9. Adjust RV207 (R DRIVE) so that the lower black level is
6.2
±
0.05 V DC.
10. Adjust RV202 (R CUT) so that the upper 100% white level is
9.2
±
0.05 V DC.
11. Repeat steps 9 & 10 until the items in the standards are satisfied.
12. Connect the oscilloscope to CL43 of the monitor main board.
13. Adjust RV209 (B DRIVE) so that the upper 100% white level
is 6.1
±
0.05 V DC.
14. Adjust RV204 (B CUT) so that the upper 100% white level is
9.1
±
0.05 V DC.
15. Repeat steps 13 & 14 until the items in the standards are satisfied.
1
2
3
4
5
6
7
8
white level (1st step)
black level (8th step)
0 V
Connection points : Monitor main board Refer to page 5.
Alignment points : Monitor main board Refer to page 5.
Page of 28
Display