Read Sony XR-C2600 Service Manual online
10
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
5.89 mN•m
more than 60 g
Reverse
CQ-403R
(more than 2.12 oz)
SECTION 3
MECHANICAL ADJUSTMENTS
SECTION 4
ELECTRICAL ADJUSTMENTS
1. Clean the following parts with a denatured-alcohol-moistened
swab:
playback head
pinch roller
rubber belt
capstan
idler
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the power supply
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the power supply
voltage (14.4 V) unless otherwise noted.
• Torque Measurement
Mode
Torque Meter
Meter Reading
2.46 – 5.39 mN•m
Forward
CQ-102C
25 – 55 g•cm
(0.35 – 0.76 oz•inch)
Forward
0.15 – 0.39 mN•m
Back Tension
CQ-102C
1.5 – 4 g•cm
(0.02 – 0.06 oz•inch)
2.46 – 5.39 mN•m
Reverse
CQ-102RC
25 – 55 g•cm
(0.35 – 0.76 oz•inch)
Reverse
0.15 – 0.39 mN•m
Back Tension
CQ-102RC
1.5 – 4 g•cm
(0.02 – 0.06 oz•inch)
4.91 – 14.70 mN•m
FF, REW
CQ-201B
50 – 150 g•cm
(0.69 – 2.08 oz•inch)
• Tape Tension Measurement
TEST MODE
This set have the test mode function. In the test mode, FM Auto
Seek/Stop Level and AM Auto Seek/Stop Level Check can be per-
formed easier than it in ordinary procedure.
Seek/Stop Level and AM Auto Seek/Stop Level Check can be per-
formed easier than it in ordinary procedure.
<Set the Test Mode>
1. Turn ON the regulated power supply. (All LEDs on the set
1. Turn ON the regulated power supply. (All LEDs on the set
lights up, and the clock is displayed.)
Note:
Press the
[OFF]
button, if the clock is not displayed.
2. Push the presett
[4]
button.
3. Push the preset
[5]
button.
4. Press the preset
[1]
button for more than two seconds.
5. Then the display indicates all lights, the test mode is set.
<Release the Test mode>
Push the [OFF] button.
Push the [OFF] button.
See the adjustment location from on page 13 for the
adjustment.
adjustment.
TAPE DECK SECTION
0 dB= 0.775 V
1. The adjustments should be performed in the order given in
this service manual.
2. The adjustments should be performed for both L-CH and
R-CH.
Test Tape
PB Head Azimuth Adjustment
Procedure:
1. Put the set into the FWD PB mode.
1. Put the set into the FWD PB mode.
2. Turn the screw and check the output peak value. Adjust the
screw so that the peak value in channels L and R coincides
within 2 dB.
within 2 dB.
Type
Signal
Used for
P-4-A063
6.3 kHz, –10 dB
head azimuth adjustment
WS-48A
3 kHz, 0 dB
tape speed adjustment
screw
position
position
L-CH
peak
peak
within
2 dB
2 dB
output
level
level
L-CH
peak
peak
R-CH
peak
peak
within
2 dB
2 dB
angle
R-CH
peak
peak
level
meter
test tape
P-4-A063
(6.3 kHz, –10 dB)
P-4-A063
(6.3 kHz, –10 dB)
set
AUDIO OUT jack (CN400)
10 k