XR-4790, XR-4800, XR-7850 (serv.man2) - Sony Car Audio Service Manual (repair manual). Page 13

Read Sony XR-4790 / XR-4800 / XR-7850 (serv.man2) Service Manual online

– 13 –
SECTION  4
MECHANICAL  ADJUSTMENTS
SECTION  5
ELECTRICAL  ADJUSTMENTS
1. Clean the following parts with a denatured-alcohol-moistened
swab:
playback head
pinch roller
rubber belt
capstan
idlers
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the power supply
voltage unless otherwise noted.
Torque Measurement
Mode
Torqu Meter
Meter Reading
Forward
CQ-403A
more than 90 g
(more than 3.18 oz)
Reverse
CQ-403R
more than 90 g
(more than 3.18 oz)
 Tape Tension  Measurement
Mode
Torqu Meter
Meter Reading
Forward
CQ-102C
30 - 65 g•cm
(0.42 - 0.90 oz•inch)
Forward
CQ-102C
0.5 - 4.5g•cm
Back Tension
(0.01 - 0.06 oz•inch)
Reverse
CQ-102RC
30 - 65 g•cm
(0.42 - 0.90 oz•inch)
Reverse
CA-102RC
0.5 - 4.5g•cm
Back Tension
(0.01 - 0.06 oz•inch)
FF, REW
CQ-201B
60 - 200 g•cm
(0.83 - 2.78 oz•inch)
TEST  MODE
This set have the test mode function. In the test mode, FM Auto
Scan/Stop Level and AM (MW) Auto Scan/Stop Level adjustments
can be performed easier than it in ordinary procedure.
<Set the Test Mode>
1. Set the “power select” switch (S801) is “A” position.
2. Turn ON the regulated power supply. (All LEDs on the set
lights up, and the clock is displayed.)
Note:
  Press the 
[OFF]
 button, if the clock is not displayed.
3. Push the preset 
[4]
 button.
4. Push the preset 
[5]
 button.
5. Press the preset 
[1]
 button for more than two seconds.
6. Then the display indicates all lights, the test mode is set.
<Release the Test mode>
1. Push the 
[OFF]
 button.
2. Return the “power select” switch (S801) to initially set posi-
tion.
See the adjustment location from on page 16 for the
adjustment.
0 dB= 0.775 V
TAPE  DECK  SECTION
Tape Speed Adjustment
Setting:
Speed checker
Frequency counter
–1.5 to +2.5%
2,955 to 3,075Hz
Procedure:
1. Put the set into the FWD PB mode.
2. Adjust adjustment resistor for inside capastan motor so that
the reading on the speed checker or frequency counter becomes
in specification.
Specification: Constant speed
+
test tape
WS-48A
(3 kHz, 0 dB)
speed checker
or
frequency counter
10 k
 
set
LINE OUT 
Adjustment Location: See page 16.
Page of 33
Display

Click on the first or last page to see other XR-4790 / XR-4800 / XR-7850 (serv.man2) service manuals if exist.