Read Sony XR-3753 / XR-C353 Service Manual online
– 14 –
SECTION 4
MECHANICAL ADJUSTMENTS
1. Clean the following parts with a denatured-alcohol-moistene
swab:
playback head
pinch roller
rubber belt
capstan
idlers
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the power supply
voltage unless otherwise noted.
•
Torque Measurement
Mode
Torqu Meter
Meter Reading
Forward
CQ-102C
30 – 65 g•cm
(0.42 – 0.90 oz•inch)
Forward
CQ-102C
0.5 – 4.5 g•cm
Back Tension
(0.01 – 0.06 oz•inch)
Reverse
CQ-102RC
30 – 65 g•cm
(0.42 – 0.90 oz•inch)
Reverse
CA-102RC
0.5 – 4.5 g•cm
Back Tension
(0.01 – 0.06 oz•inch)
FF, REW
CQ-201B
60 – 200 g•cm
(0.83 – 2.78 oz•inch)
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 90 g
(more than 3.18 oz)
Reverse
CQ-403R
more than 90 g
(more than 3.18 oz)
•
Tape Tension Measurement
SECTION 5
ELECTRICAL ADJUSTMENTS
TEST MODE
This set have the test mode function. In the test mode, FM Auto
Scan/Stop Level and AM (MW) Auto Scan/Stop Level adjustments
can be performed easier than it in ordinary procedure.
Scan/Stop Level and AM (MW) Auto Scan/Stop Level adjustments
can be performed easier than it in ordinary procedure.
<Set the Test Mode>
1. Set the “power select” switch (S501) is “A” position.
2. Turn ON the regulated power supply. (All LEDs on the set
1. Set the “power select” switch (S501) is “A” position.
2. Turn ON the regulated power supply. (All LEDs on the set
lights up, and the clock is displayed.)
Note: Press the OFF button, if the clock is not displayed.
Note: Press the OFF button, if the clock is not displayed.
3. Push the preset 4 button.
4. Push the preset 5 button.
5. Press the preset 1 button for more than two seconds.
6. Then the display indicates all lights, the test mode is set.
4. Push the preset 5 button.
5. Press the preset 1 button for more than two seconds.
6. Then the display indicates all lights, the test mode is set.
<Release the Test mode>
1. Push the OFF button.
2. Return the “power select” switch (S501) to initially aet posi-
1. Push the OFF button.
2. Return the “power select” switch (S501) to initially aet posi-
tion.
See the adjustment location from on page 17 for the
adjustment.
adjustment.
0 dB=0.775 V
TAPE DECK SECTION
Tape Speed Adjustment
Procedure:
1. Put the set into the FWD PB mode.
1. Put the set into the FWD PB mode.
Speed checker
Frequency counter
–1.5 to +2.5%
2,955 to 3,075 Hz
Specification: Constant speed
Adjustment Location: See page 17.
set
+
–
test tape
WS-48A
(3 kHz, 0 dB)
WS-48A
(3 kHz, 0 dB)
speaker out terminal
4
Ω
speed checker
or
frequency counter
Click on the first or last page to see other XR-3753 / XR-C353 service manuals if exist.