XR-1100 - Sony Car Audio Service Manual (repair manual). Page 14

Read Sony XR-1100 Service Manual online

14
XR-1100
TAPE  DECK  SECTION
0 dB= 0.775 V
1. The adjustments should be performed in the order given in
this service manual.
2. The adjustments should be performed for both L-CH and
R-CH.
Test Tape
PB Head Azimuth Adjustment
Procedure:
1. Put the set into the FWD PB mode.
2. Turn the screw and check the output peak value.  Adjust the
screw  so that the peak value in channels L and R coincides
within 3 dB.
3. Check the phase in the FWD PB mode.
4. Repeat the above adjustment for the REV PB mode.
5. Check that output level difference between FWD PB mode
and REV PB mode is within 4 dB.
SECTION  3
MECHANICAL  ADJUSTMENTS
SECTION  4
ELECTRICAL  ADJUSTMENTS
Type
 Signal
 Used for
P-4-A063
6.3 kHz, –10 dB
head azimuth adjustment
WS-48A
3 kHz, 0 dB
tape speed adjustment
level 
meter
test tape 
P-4-A063
(6.3 kHz, –10 dB)
set
speaker out terminal 
+
screw
position
L-CH
peak
within
3 dB
output
level
L-CH
peak
R-CH
peak
within
3 dB
angle
R-CH
peak
test tape 
P-4-A063
(6.3 kHz, –10 dB)
L-CH
R-CH
speaker out terminal
oscilloscope
V
H
+ +
Screen pattern
in phase
good
wrong
45 
°
90 
°
135 
°
180 
°
set
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 60 g
Reverse
CQ-403R
(more than 2.12 oz)
• Tape Tension  Measurement
1. Clean the following parts with a denatured-alcohol-moistened
swab:
playback head
pinch roller
rubber belt
capstan
idler
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the power supply
voltage (14.4 V) unless otherwise noted.
Note:
With this set, it is not necessary to apply suitable locking
compound to the parts after the azimuth adjustment.
• Torque  Measurement
Mode
Torque Meter
Meter Reading
2.46 – 5.39 mN•m
Forward
CQ-102C
(25 – 55 g•cm)
(0.35 – 0.76 oz•inch)
Forward
0.15 – 0.39 mN•m
CQ-102C
(1.5 – 4 g•cm)
Back Tension
(0.02 – 0.06 oz•inch)
2.46 – 5.39 mN•m
Reverse
CQ-102RC
(25 – 55 g•cm)
(0.35 – 0.76 oz•inch)
Reverse
0.15– 0.39 mN•m
CQ-102RC
(1.5 –
 
4 g•cm)
Back Tension
(0.02 – 0.06 oz•inch)
4.91 – 14.70 mN•m
FF, REW
CQ-201B
(50 – 150 g•cm)
(0.69 – 2.08 oz•inch)
Page of 34