XMM-R5WL, XVM-F65WL - Sony Car Audio Service Manual (repair manual). Page 12

Read Sony XMM-R5WL / XVM-F65WL Service Manual online

12
XVM-F65WL
SECTION 5
ELECTRICAL ADJUSTMENTS
5-1. EQUIPMENT USED
The following measuring equipment are used for these electrical
adjustments:
• Oscilloscope
• NTSC pattern generator
• Stabilized power supply
• Digital voltmeter
• Frequency counter
5-2. CONNECTION OF EQUIPMENT
Unless otherwise specified, the equipment should be connected as
shown below.
5-3. SETUP FOR ADJUSTMENT
The 10-step gray scale signal from the NTSC pattern generator is
used as an adjustment signal for V COM voltage/position adjustment
as well as VIDEO adjustment.
10-step gray scale signal (with burst), 1Vp-p, 75 
5-4. DC-DC CONVERTER ADJUSTMENT
5-4-1. Frequency Adjustment
Adjustment Method:
1) Connect frequency counter between TP702 (+) and TP704 (–).
2) Adjust RV702 so that the reading on the counter stands at the
specified value.
Specified value: 243 
± 3 kHz
Adjustment location: Monitor board
5-4-2. 5V Voltage Adjustment
Adjustment Method:
1) Connect digital voltmeter between TP707 (+) and TP710 (–).
2) Adjust RV701 so that the reading on the voltmeter stands at the
specified value.
Specified value: 5.05 
± 0.03 V
Adjustment location: Monitor board
5-4-3. Other Voltage Checks
Checking Method:
1) Connect digital voltmeter between TP708 (+) (Vdd) and
TP710 (–).
2) Verify that the reading on the voltmeter is at 3.20 
± 0.2 V.
3) Connect digital voltmeter between TP706 (+) (Vgh) and
TP710 (–).
4) Verify that the reading on the voltmeter is at 7.3 
± 0.3 V.
5) Connect digital voltmeter between TP705 (+) (Vgh) and
TP710 (–).
6) Verify that the reading on the voltmeter is at 17.0 
± 1.5 V.
7) Connect digital voltmeter between TP709 (+) (Vss) and
TP710 (–).
8) Verify that the reading on the voltmeter is at –12.0 
± 1.5 V.
Checking location: Monitor board
5-5. PLL ADJUSTMENT
1. Frequency Adjustment
Adjustment Method:
1) Connect digital voltmeter between TP651 (+) and TP652 (–).
2) Adjust RV651 so that the reading on the voltmeter stands at the
specified value.
Specified value: 2.2 
± 0.15 V
Adjustment location: Monitor board
VIDEO OUT
(75 Ω)
NTSC pattern
generator
MONITOR
board
TP501(+)
TP502(–)
monitor
XVM-F65WL
connection box
XA-125/126
stabilized
power supply
14.4 V
GND
P
ARK
BA
TT
Page of 52
Display

Click on the first or last page to see other XMM-R5WL / XVM-F65WL service manuals if exist.