54
XAV-7W
Pin No.
Pin Name
I/O
Description
54
VCC
—
Power supply terminal (+5V)
55
ST-BY
O
Standby on/off control signal output to the power amplifier
“L”: standby mode, “H”: amplifier on
“L”: standby mode, “H”: amplifier on
56
NS-MASK
O
Discharge control signal output terminal for the noise detection circuit “H”: discharge
57
DDC-ON
O
System power supply on/off control signal output “H”: power on
58
SIDEBRK
I
Sidebreake state detection signal input “L”: at stopping, “H”: at running
59
RGB SEL
O
RGB signal selection signal output to the display controller “L”: video, “H”: RGB (navi)
60
KEY ILL
O
Key illumination LED drive signal output “H”: LED on
61
OPNCLS
I
OPEN/CLOSE key input terminal
62
AMUTE
O
Audio line muting on/off control signal output to the monitor internal power amplifier
“L”: muting on Not used
“L”: muting on Not used
63
VSS
—
Ground terminal
64
NCO
O
Not used
65
PWM
I
For frequency counting signal input from the power control
66 to 68
NCO
O
Not used
69
FLASH-W
I
Internal flash memory data write mode detection signal input terminal “L”: data write mode
70
I2C-SDA
I/O
Two-way data I2C bus with the tuner unit, RDS decoder and electrical volume
71
I2C-SCL
I/O
I2C bus clock signal input/output to with tuner unit , RDS decoder and electrical volume
72
RC-IN1
I
Rotary remote commander shift key input terminal “L”: shift key on
73
X1A
O
Sub system clock output terminal (32.768 kHz)
74
X0A
I
Sub system clock input terminal (32.768 kHz)
75
DAVN
I
Synchronized detection signal of RDS data block input from the RDS decoder “L” active
76
NCO
O
Not used
77
BU IN
I
Battery detection signal input from the SONY bus interface
“L” is input at low voltage
“L” is input at low voltage
78
NCO
O
Not used
79
KEY ACK
I
Input of acknowledge signal for the key entry Acknowledge signal is input to accept function
keys in the power off status On at input of “H”
keys in the power off status On at input of “H”
80
AD-ON
O
A/D converter power control signal output
When the KEY ACK (pin ul) that controls reference voltage power for key A/D conversion
input is active, “L” is output from this terminal to enable the input
When the KEY ACK (pin ul) that controls reference voltage power for key A/D conversion
input is active, “L” is output from this terminal to enable the input
81
ACCIN
I
Accessory detection signal input “L”: accessory on
82
BACK SEN
I
Back gear interrupt signal input terminal “L” active Not used
83
P-ON
O
Audio power supply on/off control signal output “H”: power on
84
TEST-IN
I
Setting terminal for the test mode “H”: test mode, Normally: fixed at “L”
85
RAM-BU
I
Internal RAM reset detection signal input from the reset signal generator
Input terminal to check that RAM data are not destroyed due to low voltage
“L”: RAM clear, “H”: RAM destruction check
Input terminal to check that RAM data are not destroyed due to low voltage
“L”: RAM clear, “H”: RAM destruction check
86
HSTX
I
Hardware standby signal input terminal “L”: hardware standby mode
Reset signal input in this set
Reset signal input in this set
87
MD2
I
Setting terminal for the CPU operational mode (fixed at “L” in this set)
88, 89
MD1, MD0
I
Setting terminal for the CPU operational mode (fixed at “H” in this set)
90
RSTX
I
System reset signal input from the reset signal generator and reset switch “L”: reset
“L” is input for several 100 msec after power on, then it changes to “H”
“L” is input for several 100 msec after power on, then it changes to “H”
91
VSS
—
Ground terminal
92
X0
I
Main system clock input terminal (3.58 MHz)
93
X1
O
Main system clock output terminal (3.58 MHz)
94
VCC
—
Power supply terminal (+5V)
Click on the first or last page to see other XAV-7W (serv.man2) service manuals if exist.