XAV-7W (serv.man2) - Sony Car Audio Service Manual (repair manual). Page 54

Read Sony XAV-7W (serv.man2) Service Manual online

54
XAV-7W
Pin No.
Pin Name
I/O
Description
54
VCC
Power supply terminal (+5V)
55
ST-BY
O
Standby on/off control signal output to the power amplifier
“L”: standby mode, “H”: amplifier on
56
NS-MASK
O
Discharge control signal output terminal for the noise detection circuit   “H”: discharge
57
DDC-ON
O
System power supply on/off control signal output    “H”: power on
58
SIDEBRK
I
Sidebreake state detection signal input    “L”: at stopping, “H”: at running
59
RGB SEL
O
RGB signal selection signal output to the display controller    “L”: video, “H”: RGB (navi)
60
KEY ILL
O
Key illumination LED drive signal output    “H”: LED on
61
OPNCLS
I
OPEN/CLOSE key input terminal
62
AMUTE
O
Audio line muting on/off control signal output to the monitor internal power amplifier
“L”: muting on    Not used
63
VSS
Ground terminal
64
NCO
O
Not used
65
PWM
I
For frequency counting signal input from the power control
66 to 68
NCO
O
Not used
69
FLASH-W
I
Internal flash memory data write mode detection signal input terminal    “L”: data write mode
70
I2C-SDA
I/O
Two-way data I2C bus with the tuner unit, RDS decoder and electrical volume
71
I2C-SCL
I/O
I2C bus clock signal input/output to with tuner unit , RDS decoder and electrical volume
72
RC-IN1
I
Rotary remote commander shift key input terminal    “L”: shift key on
73
X1A
O
Sub system clock output terminal (32.768 kHz)
74
X0A
I
Sub system clock input terminal (32.768 kHz)
75
DAVN
I
Synchronized detection signal of RDS data block input from the RDS decoder    “L” active
76
NCO
O
Not used
77
BU IN
I
Battery detection signal input from the SONY bus interface
“L” is input at low voltage
78
NCO
O
Not used
79
KEY ACK
I
Input of acknowledge signal for the key entry    Acknowledge signal is input to accept function 
keys in the power off status    On at input of “H”
80
AD-ON
O
A/D converter power control signal output
When the KEY ACK (pin ul) that controls reference voltage power for key A/D conversion 
input is active, “L” is output from this terminal to enable the input
81
ACCIN
I
Accessory detection signal input    “L”: accessory on
82
BACK SEN
I
Back gear interrupt signal input terminal    “L” active    Not used
83
P-ON
O
Audio power supply on/off control signal output    “H”: power on
84
TEST-IN
I
Setting terminal for the test mode    “H”: test mode, Normally: fixed at “L”
85
RAM-BU
I
Internal RAM reset detection signal input from the reset signal generator
Input terminal to check that RAM data are not destroyed due to low voltage
 “L”: RAM clear, “H”: RAM destruction check
86
HSTX
I
Hardware standby signal input terminal    “L”: hardware standby mode
Reset signal input in this set
87
MD2
I
Setting terminal for the CPU operational mode (fixed at “L” in this set)
88, 89
MD1, MD0
I
Setting terminal for the CPU operational mode (fixed at “H” in this set)
90
RSTX
I
System reset signal input from the reset signal generator and reset switch    “L”: reset
“L” is input for several 100 msec after power on, then it changes to “H”
91
VSS
Ground terminal
92
X0
I
Main system clock input terminal (3.58 MHz)
93
X1
O
Main system clock output terminal (3.58 MHz)
94
VCC
Power supply terminal (+5V)