Read Sony CX-LFAV500 / XR-FAV500 Service Manual online
18
CX-LFAV500
Connecting Location:
– BD BOARD (Conductor Side) –
IC101
TP7
(VC)
(VC)
IC103
RV101
E-F Balance
(1 Track Jump)
Adjustment
E-F Balance
(1 Track Jump)
Adjustment
TP8
(RFAC)
(RFAC)
TP6
(RFDC)
(RFDC)
TP4
(FE)
(FE)
TP2
(TE)
(TE)
+
–
–
BD board
TP2 (TE)
TP7 (VC)
oscilloscope
Traverse Waveform
0V
B
level: 1.0
±
0.5 Vp-p
Center of
the waveform
the waveform
A (DC
voltage)
Traverse Waveform
0V
Tracking servo
Sled servo
ON
C (DC
voltage)
voltage)
Tracking servo
Sled servo
OFF
6.
Press the CD
u
button. (The tracking servo and sledding
servo are turned ON)
Rotate RV101 on BD board and adjust the C (DC voltage)
is almost equal to the A (DC voltage) in step 4.
Rotate RV101 on BD board and adjust the C (DC voltage)
is almost equal to the A (DC voltage) in step 4.
7. To exit from this mode, turn the power off.
Notes:
• Always move the optical pick-up to most inside track when
exiting from this mode. Otherwise, a disc will not be unloaded.
• Do not run the sled motor excessively, otherwise the gear can
be chipped.
E-F Balance Adjustment
Connection:
Procedure:
1.
1.
Connect an oscilloscpe to test point TP2 (TE) and TP7 (VC)
on the BD board.
on the BD board.
2.
AC is put in pushing CD
u
button to enter the CD test
mode.
3.
Put the disc (YEDS-18) in to playback the number five track.
4.
Press the button. If it plays, press the
CD
u
button again. (The tracking servo and the sledding servo are
turned OFF)
turned OFF)
5.
Check the level B of the oscilliscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than
± 10%
CD