Read Sony CDX-GT65UIW Service Manual online
CDX-GT65UIW
4
NOTE FOR REPLACEMENT OF THE USB CONNEC-
TOR (CN971) AND THE AUX JACK (J901)
To replace the USB connector and the AUX jack requires align-
ment.
1. Insert the USB connector and the AUX jack into the front pan-
TOR (CN971) AND THE AUX JACK (J901)
To replace the USB connector and the AUX jack requires align-
ment.
1. Insert the USB connector and the AUX jack into the front pan-
el.
2. Place the KEY board on the front panel and align the terminals
of the USB connector and the AUX jack with the holes in the
KEY board.
KEY board.
3. Solder four terminals of the connector and three terminals of
the jack.
SERVO board
(CN401)
(CN401)
MAIN board
(CN701)
(CN701)
extention cable (CD mecha)
KEY board
front panel
USB (socket) connector
AUX jack
TEST DISCS
Use following TEST DISC when this set confi rms the operation
and checks it.
Use following TEST DISC when this set confi rms the operation
and checks it.
Part No.
Description
3-702-101-01
YEDS-18 (for CD)
4-225-203-01
PATD-012 (for CD)
NOTE FOR THE 20-PIN CONNECTOR (CN901)
Do not use alcohol to clean the 20-pin connector (CN901) connect-
ing the front panel with the main body.
Do not touch the connector directly with your bare hand. Poor con-
tact may be caused.
Do not use alcohol to clean the 20-pin connector (CN901) connect-
ing the front panel with the main body.
Do not touch the connector directly with your bare hand. Poor con-
tact may be caused.
NOTE FOR REPLACEMENT OF THE SERVO BOARD
When repairing, the complete SERVO board should be replaced
since any parts in the SERVO board cannot be repaired.
When repairing, the complete SERVO board should be replaced
since any parts in the SERVO board cannot be repaired.
NOTE FOR REPLACEMENT OF THE SENSOR BOARD
When SENSOR board is defective, exchange the MECHANICAL
BLOCK ASSY (P).
When SENSOR board is defective, exchange the MECHANICAL
BLOCK ASSY (P).
EXTENSION CABLE AND SERVICE POSITION
When repairing or servicing this set, connect the jig cable (exten-
sion cable (CD mecha)) as shown below.
When repairing or servicing this set, connect the jig cable (exten-
sion cable (CD mecha)) as shown below.
• Connect the MAIN board (CN701) and the SERVO board
(CN401) with the jig cable.
Jig cable:
Part No.
Part No.
Description
A-1818-424-A
EXTENSION CABLE (CD MECHA)