Read Sony CDX-C780R Service Manual online
– 28 –
MW Auto Scan/Stop Level Adjustment
Setting :
SOURCE
n MODE button : MW
Procedure :
1. Set to the test mode. (See page 26.)
2. Push the SOURCE button.
3. Push the MODE button and set to MW.
1. Set to the test mode. (See page 26.)
2. Push the SOURCE button.
3. Push the MODE button and set to MW.
Display
4. Push the preset 3 button.
Display
5. Adjust with the volume RV1 on TU10 so that the “MW”
indication turns to “MW0” indication on the display window.
But, in case of already indicated “MW0”, turn the RV1 so that
put out light “0” indication and adjustment.
But, in case of already indicated “MW0”, turn the RV1 so that
put out light “0” indication and adjustment.
Display
Carrier frequency : 999 kHz
30% amplitude
modulation by
1 kHz signal
output level
30% amplitude
modulation by
1 kHz signal
output level
: 33 dB (44.7
µ
V)
Adjustment Location : See page 29.
AM RF signal
generator
generator
antenna
terminal
terminal
AM dummy
antenna(50
antenna(50
Ω
)
30
Ω
65 pF
15 pF
set
TP
SHUF
REG
TP
SHUF
REG
TP
SHUF
REG
Carrier frequency : 98.00 MHz
Output level
Output level
: 35 dB (56.2
µ
V)
Mode
: mono
Modulation
: no modulation
Procedure :
1. Set to the test mode. (See page 26.)
2. Push the SOURCE button and set to FM.
1. Set to the test mode. (See page 26.)
2. Push the SOURCE button and set to FM.
Display
FM RDS S-Meter Adjustment
Setting :
SOURCE button : FM
3. Push the preset 10 button.
4. Adjust RV10 so that the display indication is “13.0”.
4. Adjust RV10 so that the display indication is “13.0”.
Display
Specification : Display indication : 12.8 to 13.2.
Adjustment Location : See page 29.
FM RF signal
generator
generator
antenna
terminal
terminal
0.01
µ
F
set
SHUF
REG
SHUF
REG
Click on the first or last page to see other CDX-C780R service manuals if exist.