CDX-4170R - Sony Car Audio Service Manual (repair manual). Page 20

Read Sony CDX-4170R Service Manual online

– 20 –
SECTION 3
ELECTRICAL ADJUSTMENTS
TEST MODE
This set have the test mode function. In the test mode, FM Auto
Scan/Stop Level and MW Auto Scan/Stop Level adjustments can
be performed easier than it in ordinary procedure.
<Set the Test Mode>
1. Set the “OFF” mode.
2. Push the preset  4  button.
3. Push the preset  5  button.
4. Press the preset  1  button for more than two seconds.
5. Then the display indicates all lights, the test mode is set.
<Release the Test Mode>
1. Push the  OFF  button.
  TUNER SECTION
Cautions during repair
When the tuner unit is defective, replace it by a new one because
its internal block is difficult to repair.
Note on Adjustment
The adjustments of tuner section, should be performed according
to the following sequence.
1. FM Auto Scan/Stop Level Adjustment
2. FM Noise Focus Adjustment
3. FM Stereo Separation Adjustment
4. FM RDS S-Meter Adjustment
5. MW Auto Scan/Stop Level Adjustment
0 dB = 1 
µ
V
Carrier frequency : 98.00 MHz
Output level
: 22 dB (12.6 
µ
V)
Mode
: mono
Modulation
: 1 kHz, 22.5 kHz deviation (30%)
Procedure :
1. Set to the test mode.
2. Push the  SOURCE  button and set to FM.
Display
FM Auto Scan/Stop Level Adjustment
Setting :
D-BASS switch : OFF
SOURCE button : FM
3. Push the preset  3  button.
Display
4. Adjust with the volume RV2 on TU101 so that the “FM”
indication turns to “FM0” indication on the display window.
But, in case of already indicated “FM0”, turn the RV2 so that
put out light “0” indication and adjustment.
Display
FM RF signal
generator
0.01 
µ
F
antenna
terminal
set
INTRO
REG
INTRO
REG
INTRO
REG
Adjustment Location : See page 22.
Page of 45
Display

Click on the first or last page to see other CDX-4170R service manuals if exist.