ZS-D50 (serv.man2) - Sony Audio Service Manual (repair manual). Page 16

Read Sony ZS-D50 (serv.man2) Service Manual online

– 16 –
 TUNER  SECTION
 AM Section
RADIO BAND button : MW or LW
Volume : MIN
 FM Section
RADIO BAND button : FM
Volume : MIN
Adjustment Location :  Tuner board (See page 17)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
MW/LW IF ADJUSTMENT
Adjust for a maximum reading on level meter.
CFT1
450kHz
MW  FREQUENCY COVERAGE  ADJUSTMENT
Adjust part
Frequency display
reading on digital
voltmeter.
 L4
  531kHz
 0.65 – 1.05V
CT2
1,611kHz
 5.1 – 6.1V
MW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3–1
621kHz
CT4
1,404kHz
LW FREQUENCY COVERAGE  ADJUSTMENT
Adjust part
Frequency display
reading on digital
voltmeter
CT3
279kHz
5.1 – 5.5V
Confirmation
153kHz
0.6 – 0.8V
LW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3 – 2
162kHz
CT5
261kHz
FM FREQUENCY COVERAGE  ADJUSTMENT
Adjust part
Frequency display
reading on digital
voltmeter
Confirmation
87.5MHz
1.45 – 1.85V
L2
108MHz
3.6 – 4.6V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
87.5MHz
CT1
108MHz
Frequency Coverage Adjustment
Connect Location :
[TUNER BOARD]
 
(SIDE B)
AM  RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
Put the lead-wire
antenna close to 
the set.
FM RF signal
generator
22.5kHz frequency deviation by 
400Hz signal.
Output level : as low as possible
telescopic
antenna
terminal
0.01 
µ
F
set
47k
+
LINE OUT
level meter
+
Digital
voltmeter
100 k
IC2 
 pin
Page of 52
Display