SECTION 4
ADJUSTMENTS
4-2.
ELECTRICAL ADJUSTMENT
1. Perform adjustments on the following conditions unless
otherwise specified.
• Switches and controls positions
VOL knob ···························································· Maximum
SPEED CONTROL knob ······················· Mechanical center
V•O•R switch ································································ OFF
REC TIME switch ···················································· Normal
Test tape
Tape Speed Adjustment
Procedure :
Mode : Playback (FWD)
Adjust RV602 (standard)/RV603 (double speed) until the frequency
counter reading
becomes 3,000 Hz at the standard mode and 1,500 Hz at the double
speed mode.
Specification Value :
Frequency difference between the beginning and the end of the
tape should be within 1% (30Hz).
Upon completion of adjustments, select the REV playback mode
and check that the measurement value is within the specifications.
Adjustment Location :
Test Tape
WS-48A
Used for
Tape speed adjustment
Signal
3kHz, 0dB
4-1. MECHANICAL ADJUSTMENT
PRECAUTION
1.
Clean the following parts with a denatured-alchool-moistened
swab:
record/playback/erase head pinch roller
head
rubber belts
capstans
idlers
2.
Demagnetize the record/playback/erase head with a head
demagnetizer. (Do not bring the head demagnetizer close to
the erase head.)
3.
Do not use a magnetized screwdriver for the adjustments.
4.
After the adjustments, apply suitable locking compound to the
parts adjusted.
5.
Unless specified otherwise, use a specified voltage (3.0V) to
perform the adjustments.
Torque Measurement
Meter Reading
20 – 35g•cm
0.28 – 0.48 oz•inch
0.5 – 5.0g•cm
0.007 – 0.07 oz•inch
20 – 35g•cm
0.28 – 0.48 oz•inch
0.5 – 5.0g•cm
0.007 – 0.07 oz•inch
more than 40g•cm
more than 0.5 oz•inch
Mode
FWD
FWD
back tension
FWD
FWD
back tension
FF
REW
Torque Meter
CQ-102C
CQ-102RC
CQ-201B
0dB = 0.775V
16 
set
Headphone jack(J303)
+
test tape 
WS-48A
(3kHz, 0dB)
digital frequency
counter
RV602(NORMAL)
RV603(HIGH)
Digital frequency counter
2,970 – 3,030Hz
1,485 – 1,515Hz
Tape speed
RV602(Normal)
RV603(High)