SECTION  5
ELECTRICAL  ADJUSTMENTS
Tape Speed Adjustment
Setting:
Procedure:
– Normal –
1. Set the 
[REC TIME]
 switch (S601) to 
[NORMAL]
 position.
2. Playback WS-48A (tape center) in the FWD state.
3. Adjust RV601 so that the frequency counter reading becomes
3,000 Hz.
Specified Value: 2,970 to 3,030 Hz
4. Check that deflection of the frequency counter reading between
the beginning and the end of tape is within 1.5% (approx. 45
Hz).
– Double (1/2 SPEED) –
1. Set the 
[REC TIME]
 switch (S601) to 
[DOUBLE]
 position.
2. Playback WS-48A (tape center) in the FWD state.
3. Adjust RV602 so that the frequency counter reading becomes
1,500 Hz.
Specified Value: 1,485 to 1,515 Hz
Adjustment Location:
PRECAUTION
1. Specified voltage
: 2.5 V (DC)
2. Setting
SPEED CONTROL dial
: center click
0 dB=0.775 V
Test Tape
Record/Playback Head Azimuth Adjustment
Setting:
Mode:  playback (normal speed)
Procedure:
1. Turn the adjustment screw to obtain the maximum reading on
level meter.
Note:
  Several peaks may appear, but take the maximum.
2. After the adjustment, lock the adjustment screw with suitable
locking compound.
Adjustment Location:
Type
Signal
 Used for
P-4-A063
6.3 kHz, –10 dB
Head Azimuth Adjustment
WS-48A
3 kHz, 0 dB
Tape Speed Adjustment
level meter
test tape
P-4-A063
(6.3 kHz, –10 dB)
US: 32 
Except US: 16 
set
i
 jack (J301)
+
adjustment screw
Press the  
button.
frequency counter
test tape 
WS-48A
(3 kHz, 0 dB)
set
i
 jack (J301)
+
US: 32 
Except US: 16 
RV602
Tape Speed Adjustment
(Double)
J301
RV601
Tape Speed Adjustment
(Normal)
J302
– MAIN BOARD (Conductor Side) –
Page of 20
Display

Click on the first or last page to see other TCS-30D service manuals if exist.