Read Sony TC-KE240 / TC-RE340 Service Manual online
13
Tape Speed Adjustment
Procedure:
Mode: playback
Mode: playback
1. Set to the test mode (See page 12).
2. Press the
2. Press the
H
button to playback.
3. Adjust RV301 so that the frequency counter reading becomes
3,000±90 Hz.
4. Frequency difference between the beginning and the end of
the tape should be within 3%.
Adjustment Location: MAIN board (See page 14)
Sample value of Wow and Flutter: 0.3% or less W.RMS (JIS)
(WS-48B)
Playback Level Adjustment
Procedure:
Mode: playback
Mode: playback
Adjust RV121 (L-CH) and RV221 (R-CH) so that the reading on
level meter meets the adjustment limits below.
level meter meets the adjustment limits below.
Adjustment Limits:
LINE OUT level: –7.7±0.5 dB (0.301 to 0.338 V)
Level difference between channels: within 0.5 dB
Level difference between channels: within 0.5 dB
Check that the LINE OUT level does not change even if playback
and stop operation is repeated several times.
and stop operation is repeated several times.
Adjustment Location: MAIN board (See page 14)
+
–
–
set
LINE OUT jack (J301)
frequency counter
test tape
WS-48B
(3 kHz, 0 dB)
WS-48B
(3 kHz, 0 dB)
47 k
Ω
+
–
–
set
LINE OUT jack (J301)
47 k
Ω
test tape
P-4-L300
(315 Hz, 0 dB)
P-4-L300
(315 Hz, 0 dB)
level meter
Bias Consumption Current Adjustment (TC-RE340 only)
Procedure:
1. Set RV141 (L-CH) and RV241 (R-CH) to mechanical center
and turn the set recording mode.
2. Connect digital voltmeter as shown by the following table.
3. Press the H button to playback.
4. Adjust the following transformers for the minimum readings
3. Press the H button to playback.
4. Adjust the following transformers for the minimum readings
on the digital voltmeter.
Measurement Point
Adjustment Part
Value
L-CH
TP301 pin 2 and 3
T101
minimum
R-CH
TP301 pin 1 and 2
T201
Specified value: Maximum 220 mV
Adjustment Location: MAIN board (See page 14)
Record Bias Adjustment
Setting:
[REC LEVEL]
volume: standard record position (See page 12)
Procedure:
Mode: record and playback
Mode: record and playback
1. Set to the test mode (See page 12).
2. Press the
2. Press the
[REC ]
button then the
H
button to start record-
ing.
3. Press the
x
button to stop recording and press the
H
button
to playback.
4. Adjust TC-KE240: RV142 (L-CH) and RV242 (R-CH), TC-
RE340: RV141 (L-CH) and RV241 (R-CH) so that 10 kHz
playback output is 0±0.3 dB relative to the 315 Hz output.
playback output is 0±0.3 dB relative to the 315 Hz output.
Adjustment Location: MAIN board (See page 14)
–
+
+
set
LINE IN jack (J301)
(no signal)
(no signal)
TP301
3
2
1
L-CH
R-CH
47 k
Ω
digital voltmeter
CS-413 blank tape
set
47 k
Ω
AF OSC
Attenuator
LINE IN jack (J301)
315 Hz
10 kHz
315 Hz
10 kHz
50 mV (–23.8 dB)
600
Ω
10 k
Ω
CS-123
blank tape
blank tape
LINE OUT jack (J301)
level meter
+
–
TC-KE240
TC-RE340
adjustment screw
adjustment screw
z
Adjustment Location: record/playback head
Click on the first or last page to see other TC-KE240 / TC-RE340 service manuals if exist.