SECTION  3
TEST  MODE
COLD  RESET
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  S-AIR ID slide switch select the “A”.
3.  Press the [PAIRING] button, and hold for 5 seconds (not re-
lease the this button up to step 5).
4. Confi rm the PAIRING indicator LED is blinks.
5.  Press the [PAIRING] button, and hold for 15 seconds.
6. Confi rm the S-AIR/STANDBY indicator LED is orange light-
ing. Initialization was completed.
7.  The AC plug is pulled out to turn off the system.
 
Please insert it after confi rming LED has been turned off when 
you insert the AC plug again.