STR-V333ES, STR-V444ES, STR-V555ES - Sony Audio Service Manual (repair manual). Page 3

Read Sony STR-V333ES / STR-V444ES / STR-V555ES Service Manual online

3
AM tuner section
Tuning range
With 10-kHz tuning
scale:
530 – 1710 kHz
6)
With 9-kHz tuning
scale:
531 – 1710 kHz
6)
Antenna
Loop antenna
Usable sensitivity
50 dB/m (at 1,000 kHz
or 999 kHz)
S/N
54 dB (at 50 mV/m)
Harmonic distortion
0.5 % (50 mV/m,
400 kHz)
Selectivity
At 9 kHz:  35 dB
At 10 kHz:  40 dB
6)
Y
(US, Canadian, E, Taiwan only)
ou can change the AM tuning scale to
10 kHz 9 kHz.  After tuning in any AM
station, turn off the receiver.  Hold down the
TUNING + button and press the  ?/1
button.  All pr eset stations will be erased
when you change the tuning scale.  To reset
the scale to 10 kHz (or 9 kHz), repeat the
procedure.
Video section
Inputs
Video: 1 Vp-p 75 ohms
S-video:
Y: 1 Vp-p  75 ohms
C: 0.286 Vp-p
75 ohms
Component video
(STR-V444ES, 
Y: 1 Vp-p  75 ohms
B-Y:  1 Vp-p 75 ohms
R-Y:  1 Vp-p 75 ohms
Outputs
Video: 1 Vp-p 75 ohms
S-video:
Y: 1 Vp-p  75 ohms
C: 0.286 Vp-p
75 ohms
Component video
(STR-V444ES, 
Y:  1 Vp-p 75 ohms
B-Y:  1 Vp-p 75 ohms
R-Y:  1 Vp-p 75 ohms
STR-V555ES
STR-V333ES, STR-V444ES
Models of ar ea code UC
With 10-kHz tuning
scale:
530 – 1710 kHz
6)
With 9-kHz tuning
scale:
531 – 1710 kHz
6)
Models of area code CN, CED, TW, E
With 9-kHz tuning
scale:
531 – 1602 kHz
STR-V555ES):
STR-V555ES):
General
System
Tuner section:
PLL quartz-locked
digital synthesizer
system
Preamplifier section:
Low-noise NF type
equalizer
Power amplifier
section:
Pure-complementary
SEPP
Power requirements
Power consumption
STR-V444ES
STR-V555ES
STR-V555ES
STR-V555ES
420 W
STR-V333ES
STR-V333ES, STR-V444ES
410 W
AC outlets
2 switched,
total 120 W/1A
Dimensions
430 
× 175 × 405 mm
(17 
× 7 × 16 in.)
including projecting
parts and controls
Mass (Approx.)
STR-V444ES, STR-V555ES
17.0 kg (37 lb 8 oz)
STR-V333ES
16.0 kg (35 lb 4 oz)
Models of area code UC
120 V AC, 60 Hz
STR-V333ES, STR-V444ES
120 V AC, 60 Hz
Models of area code
CED
230 V AC, 50/60 Hz
Models of area code CN
220 – 230 V AC,
50/60 Hz
Models of area code E
120/220/240 V  AC,
50/60 Hz
Models of area code
TW
110 V AC, 60 Hz
Models of ar ea code UC
420 W
Models of ar ea code
CED, CN
370 W
Models of ar ea code
E, TW
420 W
Models of ar ea code UC
2 switched,
total 120 W/1A
Models of ar ea code
CED
1 switched,
total 100 W
Models of ar ea code
E, CN,  TW
2 switched,
total 100 W
Page of 103