STR-KSL900W - Sony Audio Service Manual (repair manual). Page 6

Read Sony STR-KSL900W Service Manual online

STR-KSL900W
6
SECTION  3
ELECTRICAL ADJUSTMENT
DIAT SIGNAL RF LEVEL  ADJUSTMENT
This adjustment is performed in order to adjust the transmission
distance of RF signal for DIAT communication.
Connection:
Procedure:
1. Connect the oscilloscope to JL7003 (RF AMP OUT) and GND
on the TX board.
2. Connect DIR-T1 to DIR-T1 jack (J7001).
Note:
Be sure to connect DIR-T1 before the adjust.
3. Adjust RV7001 on the TX board so that the center of waveform
becomes 1.0 Vp-p.
4. Confirm trigger is locked.
5. Adjust RV7001 on the TX board so that the center of waveform
becomes 2.2 to 2.4 Vp-p.
RF Signal Reference Waveform
VOLT/DIV : 500 mV
TIME/DIV : 500 ns
level : 2.2 to 2.4 Vp-p
JL7003
(RF AMP OUT)
TX board
oscilloscope
– TX Board (Component Side) –
JL7003
(RF AMP OUT)
Adjustment Location:
Page of 49